CHIPDRIVE CLOUD 4700F 905511 Hoja De Datos
Los códigos de productos
905511
CLOUD
47
X
0
F
R
EFERENCE
M
ANUAL
32
6.2.2. PAPDU_MIFARE_UPDATE_BINARY
This command is used to update the non-volatile memory of a Mifare card. Refer to section
3.2.2.1.9 of [PCSC3] for further details.
3.2.2.1.9 of [PCSC3] for further details.
Command APDU
:
Command
CLA
INS
P1
P2
Lc
Data
Le
Update Binary
0xFF
0xD6
Addr MSB
Addr LSB
xx
data
-
For a description of P1 and P2, see
PAPDU_MIFARE_READ_BINARY
Lc has got to match the block size of the used card
16 bytes for Mifare Classic
4 bytes for Mifare UL and UL C
16 bytes for Mifare Classic
4 bytes for Mifare UL and UL C
Response APDU:
Data
Status Word
-
SW1, SW2
Example:
To write the bytes AA 55 AA 55 AA 55 AA 55 AA 55 AA 55 AA 55 AA 55 to block 7 of
a Mifare Classic 1K, the following command has got to be issued:
APDU:
FF D6 00 06 10 AA 55 AA 55 AA 55 AA 55 AA 55 AA 55 AA 55 AA 55
SW12:
9000 (OK)
Resulting in this content on the card: