Casafan WS 2,5 A/U 98250 98250 Manual De Usuario

Los códigos de productos
98250
Descargar
Página de 12
GB
5
Mounting instructions
These speed controllers is for use with single 
phase  voltage  controllable  motors  only.  The 
“0” position stops the fan.
Technical data:
Power supply: 230 Vac - 50/60 Hz
Current range Fuse
WS 1,5 A/U (ELY/ELX15): 1,5 A F 2,0 A - H
WS 2,5 A/U (ELY/ELX25): 2,5 A F 3,15 A - H
Enclosure external: plastic, ASA, RAL 9010 white-
ivory 
Enclosure internal: polyamide According to IEC 
60335
Max ambient temperature: 35 °C
All works may only be carried out by skilled
personnel  following  the  local  regulations 
and AFTER the controller is completely se-
parated from the mains.
Inset mounting (IP 44)
Break mains voltage. Connect according to di-
agram. Mount innercase to the wall with con-
nections pointing down. Mount cover with nut 
to the wall. Push knob in place at off position.
Surface mounting (IP 54)
Break  mains  voltage.  Mount  surface  moun-
ting case to the wall together with included 
grommets.  Connect  according  to  diagram. 
Mount  inner  case  in  surface  mounting  case 
with  included  screws.  Mount  cover  with  nut 
to surface mounting case. Push knob in place 
at off position. When needed a 5 mm hole for 
condensatation  water  is  to  be  drilled  at  the 
bottom of the surface mounting case.
Connections (fig. page 1)
1. Mains connection : 230 V - 50/60 Hz
2. Fuse-box with spare fuse. (Fast, ceramic)
3. Switched output to motor
The controller is only to be used together with  
fans that are suitable for speed control by ca-
pacitors. The motor used should be internally 
protected against over heating. 
In case of faulty operation, please check that: 
right  voltage  is  applied.  All  connections  are 
correct. The machine to be regulated is func-
tioning. The fuse in fusebox is OK. The fuse in 
the controller is OK.
Change of fuse
Undo  knob  by  first  turning  the  knob  to  the 
right beyond end stop and then pull. Remove 
the nut. Remove fuse holder with a screwdri-
ver. Change fuse. Put the details back in place. 
Use only recommended fuses (Approved, fast, 
with high breaking
capacity ) otherwise loss of warranty will en-
sue.
Warranty
One year from delivery date against defects in 
manufacturing.  Any  modifications  or  altera-
tions to the product relieve the manufacturer 
of all responsibility.
Maintenance
In normal conditions the controllers are main-
tenance-free. If soiled clean with dry or dam-
pish  cloth.  In  case  of  heavy  pollution  clean 
with  a  non-aggressive  product.  In  these  cir-
cumstances
the  controller  should  be  disconnected  from 
the mains. Pay attention that no fluids enter 
the controller. Only reconnect the controller to 
the mains when it is completely dry.
Replace fuse only with same type and rating.