19. Setting the offset temperature
Since the temperature is measured at the radiator, it can 
be colder or warmer at another location in the room. In or-
der to equalise this, a temperature offset of +/- 3.5 °C can 
be set. If for example 18 °C is measured instead of the set 
20 °C, then an offset of -2.0 °C is to be set.
To set the offset temperature proceed as follows:
•  Press the Menu key longer than 3 seconds.
•  Select the „OF“ menu item with the selector dial and con-
firm with the OK key 
•  Turn the selector dial for as long as necessary until the 
desired temperature appears. 
•  Confirm with the OK key.
20. Restoring the factory settings
The status of the programmable radiator control unit can 
be manually restored by means of a reset to that when ori-
ginally supplied. This means that all the manually perfor-
med settings are lost.
Follow these steps:
•  Hold the Menu key pressed down for longer than 3 se-
conds.
•  Select the „RES“ menu item with the selector dial and con-
firm with the OK key. „CFM“ then appears in the display.
•  „CFM“ then appears in the display.
•  Confirm with the OK key.