Gw Instek GDS-2074A 4-channel oscilloscope, Digital Storage oscilloscope, GDS-2074A Hoja De Datos

Los códigos de productos
GDS-2074A
Descargar
Página de 220
 
 
GDS-2000A Programming Manual 
40
 
Related 
Commands 
:ACQuire:AVERage 
Parameter 
SAMPle 
Sample mode sampling 
 
PDETect 
Peak detect sampling 
 
AVERage 
Average sampling mode 
Example 
:ACQuire:MODe PDETect 
Sets the sampling mode to peak detection. 
:ACQuire<X>:MEMory? 
Query
 
 
Description 
Returns the data in acquisition memory for the 
selected channel as a header + raw data.   
Syntax 
:ACQuire<X>:MEMory? 
 
Related 
Commands 
ACQuire:RECOrdlength 
:HEADer 
Parameter 
<X> 
Channel number (1 to 4) 
Example 
:ACQuire1:MEMory? 
Format,2.0A;Memory 
Length,5000;IntpDistance,0;Trigger 
Address,2499;Trigger Level,9.400E-
02;Source,CH1;Vertical Units,V;Vertical Units 
Div,0;Vertical Units Extend Div,13;Label,;Probe 
Type,0;Probe,1.000e+00;Vertical Scale,5.000e-
02;Vertical Position,-9.400e-02;Horizontal 
Units,S;Horizontal Scale,2.000E-04;Horizontal 
Position,0.000E+00;Horizontal Mode,Main;SincET 
Mode,Real Time;Sampling Period,4.000e-
07;Horizontal Old Scale,2.000E-04;Horizontal Old 
Position,0.000E+00;Firmware,V0.99.03;Time,19-
Sep-12 10:04:48;Waveform Data; #510000  <Raw 
Data> 
<LF>