Gw Instek AFG-2025 Function Generator, Frequency Generator AFG-2025 Hoja De Datos
![Gw Instek](https://files.manualsbrain.com/attachments/dc6af9cceb6bec808125ac96ad99be7dbe37566d/common/fit/150/50/51850356515eec56d4ea258553f26e4c7c86af45115072a82f444014a577/brand_logo.gif)
Los códigos de productos
AFG-2025
AFG-2000 Quick Start Guide
16
FM (2100 series only)
Example: FM modulation. 100Hz modulating square wave. 1Vpp,
1kHz Sine wave carrier. 100 Hz frequency deviation. Internal
Source.
1kHz Sine wave carrier. 100 Hz frequency deviation. Internal
Source.
Output
50
W
MAIN
1. Press FUNC>select the sine wave
2. Press FREQ>1>kHz
3. Press AMPL>1>Vpp
4. Press FM
5. Press Shift>INT/EXT>select INT
6. Press Shift>Shape>select square
7. Press Shift>Rate>1>0>0>Hz
8. Press Shift>DEP/DEV>1>0>0>Hz
9. Press Output
10. Press FM to deselect the FM function
2. Press FREQ>1>kHz
3. Press AMPL>1>Vpp
4. Press FM
5. Press Shift>INT/EXT>select INT
6. Press Shift>Shape>select square
7. Press Shift>Rate>1>0>0>Hz
8. Press Shift>DEP/DEV>1>0>0>Hz
9. Press Output
10. Press FM to deselect the FM function
FSK Modulation (2100 series only)
Example: FSK modulation. 100Hz Hop frequency. 1Vpp, 1kHz
Ramp carrier wave. 10 Hz Rate (modulation frequency). Internal
Source.
Ramp carrier wave. 10 Hz Rate (modulation frequency). Internal
Source.
Output
50
W
MAIN
1. Press FUNC>select the ramp wave
2. Press FREQ>1>kHz
3. Press AMPL>1>Vpp
4. Press FSK
5. Press Shift>INT/EXT>Select INT
6. Press Shift>Rate>1>0>Hz
7. Press Shift>HOP>1>0>0>Hz
8. Press Output
9. Press FSK to deselect the FSK function
2. Press FREQ>1>kHz
3. Press AMPL>1>Vpp
4. Press FSK
5. Press Shift>INT/EXT>Select INT
6. Press Shift>Rate>1>0>Hz
7. Press Shift>HOP>1>0>0>Hz
8. Press Output
9. Press FSK to deselect the FSK function