b) Receiver Connection
The receiver is connected to the socket “X13”. A suitable connection cable for this is supplied
with the combiboard. The connection socket “X13” has 10 contacts that are numbered from the
right to the left. Contact 10 is on the left, contact 1 on the right.
The contacts are assigned as follows:
Contact 10 = Channel 1
Contact 9 = Channel 2
Contact 8 = Channel 3
Contact 7 = Channel 4
Contact 6 = Channel 5
Contact 5 = Channel 6
Contact 4 = Channel 7
Contact 3 = Channel 8
Contact 2 = 5 V/DC/Plus (+)
Contact 1 = GND/Minus (-)
The signals of the 8 inputs (channels 1 – 8) are measured and processed by the composite
signal converter. All available signals are combined into a composite signal pursuant to the
specifications for RC remote control systems (pulse width between 1 and 2 ms). Due to measur-
ing of the signals and signal processing, there will be a delay of one frame length. However, this
has no effect during operation and is therefore only mentioned for the same of completeness.
The measured servo signals may appear in any order, parallel, in sequence or overlapping.
There are no limitations, so that the composite signal converter can be used for all common
systems. A synch break between the different signals is also not required.
To connect the receiver to the included connection cable, best use a servo connection cable.
Shorten it to the required length and then solder it to the open ends of the included receiver
connection cable. The soldering connections are then insulated with a shrink hose.
R21
X6
PAD1
X14
PAD2
Q2
C19
C18
R40
C17
C4
IC3
LD1
R42 R41
R43 LD2
R22
R21
X13
D1
X15
X6
+
-
1
10
Figure 3