Proma 140001 UV Exposure Unit with Vacuum, 135W 140001 Hoja De Datos

Los códigos de productos
140001
Descargar
Página de 8
 UV exposure device
 
I
4
Abstract: Exposure of a double-sided printed circuit board
 Creating the layout pocket
1.
Attach thin double-sided adhesive tape onto a stripe of approx. 
 mm width of base
material 
 mm).
2.
Place the tool films (solder side and component side) identically on top of each other
and glue base material between the tool films at one end.
 Exposure
1.
Remove the protective foil of the light-sensitive coated printed circuit board; place it into
the layout pocket.
2.
Place both onto the lower pane of glass (support pane). Apply pressure using the
pressure pane (mobile pane of glass).
3.
Turn-on the device and observe the pressure distribution. Close the device cover if the
low air pressure has reached approx. 
 bar (the tool film is pressed onto the printed
circuit board).
4.
Depending on the tool film, set the exposure time between 2 and 5 minutes.
5.
Check the exposure switch for double-sided exposure and press the Start push-button.
The remaining exposure time is visible on the display. Switch-off the device at the
completion of the exposure time (LED indicator flashes), press the valve push-button,
and wait until the low air pressure has risen to normal.
6.
Open the device and remove the exposed printed circuit board.
Technical data
Vakuum UV exposure devices
Typ 1
Typ 2
Typ 3
Typ 4
Exposure area
[mm]
360 x 230
360 x 230
520 x 390
520 x 390
Power consumption
135
260
225
440
Number of W tubes 
4 x 1 5
8 x 1 5
6 x 2 0
1 2 x 2 0
UV wave length
365
The device is tested to the EMC guidelines for applications in living and business areas,
laboratories and small firms.