Bourns TBU-SING,BI-DIR/TBU-CA065-300-WH/DFN/BOU TBU-CA065-300-WH Hoja De Datos

Los códigos de productos
TBU-CA065-300-WH
Descargar
Página de 6
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0.0
-75 -50 -25
0
25
50
75 100 125 150
Junction Temperature (°C)
Normalized Trip Current (A)
2.2
1.6
1.8
2.0
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0.0
-75 -50 -25
0
25
50
75 100 125 150
Junction Temperature (°C)
Normalized Resistance (
Ω
)
     TBU-CA Series - TBU
®
 High-Speed Protectors
Specifi cations are subject to change without notice.
Customers should verify actual device performance in their specifi c applications.
Reference Application
The TBU
®
 devices are general use protectors used in a wide 
variety of applications. The maximum voltage rating of the TBU
®
 
device should never be exceeded. Where necessary, an OVP 
should be employed to limit the maximum voltage. A cost-
effective protection solution combines Bourns
®
 TBU
®
 protection 
devices with a pair of Bourns
®
 MOVs. For bandwidth sensitive 
applications, a Bourns
®
 GDT may be substituted for the MOV.
The TBU
®
 device, constructed using MOSFET semiconductor 
technology, placed in the system circuit will monitor the 
current with the MOSFET detection circuit triggering to provide
an effective barrier behind which sensitive electronics are not 
exposed to large voltages or currents during surge events. The 
TBU
®
 device operates in approximately 1 μs - once line
current exceeds the TBU
®
 device’s trigger current Itrigger. 
When operated, the TBU
®
 device restricts line current to less 
than 1 mA typically. When operated, the TBU
®
 device will
block all voltages including the surge up to rated limits.
After the surge, the TBU
®
 device resets when the voltage 
across the TBU
®
 device falls to the V
reset
 level. The TBU
®
 
device will automatically reset on lines which have no DC bias 
or have DC bias below V
reset
 (such as unpowered signal lines). 
If the line has a normal DC bias above V
reset
, the voltage
across the TBU
®
 device may not fall below V
reset
 after the 
surge. In such cases, special care needs to be taken to ensure 
that the TBU
®
 device will reset, with software monitoring as one 
method used to accomplish this. Bourns application
engineers can provide further assistance.  
Basic TBU Operation
Performance Graphs
Typical V-I Characteristics (TBU-CA050-300-WH)
Typical Trigger Current vs. Temperature
Equip.
OVP
OVP
Line
Line
TBU
®
Device
TBU
®
Device
Line In / 
Line Out
Line Out 
/ Line In
Line Out 
/ Line In
Line In / 
Line Out
Typical Resistance vs. Temperature
Power Derating Curve
CURRENT
(100 mA/div)
VOLTAGE
(5 V/div)
I
TRIP
V
RESET
No Additional PCB Cu
0.5 sq. in. Additional PCB Cu
Junction Temperature (°C)
20
3.0
2.5
2.0
1.5
1.0
0.5
0.0
40
60
80
100
120
140
Total Max. Power (W)