Texas Instruments TPS61080/81-147 Evaluation Board TPS61080/81EVM-147 TPS61080EVM-147 TPS61080EVM-147 Hoja De Datos

Los códigos de productos
TPS61080EVM-147
Descargar
Página de 27
F
P
+
1
2
p
R2C1
when R1
u u
R2.
F
P
+
ǒ
1
R1
)
1
R2
Ǔ
1
2
p
C1
F
z
+
1
2
p
R1
 
C1
R1
+
R2
 
ǒ
Vout
1.229V
*
1
Ǔ
TPS61080/1
OUT
FB
R1
R2
C 1
R3
100 W
C2
4.7
F
m
SLVS644D – FEBRUARY 2006 – REVISED APRIL 2013
If the calculated duty cycle is less than 5%, minimum load should be considered to the boost output to ensure
regulation.
provides quick reference to identify the minimum load requirements for two input voltages.
APPLICATION INFORMATION
PROGRAM OUTPUT VOLTAGE
Figure 20. Feed Forward Capacitor Connecting With Feedback Resistor Divider
To program the output voltage, select the values of R1 and R2 (See
according to the following
equation.
(4)
A optimum value for R2 is around 50k
Ω
which sets the current in the resistor divider chain to 1.229V/50k
Ω
=
24.58
μ
A. The output voltage tolerance depends on the V
FB
accuracy and the resistor divider.
FEED FORWARD CAPACITOR
A feed forward capacitor on the feedback divider, shown in
improves transient response and phase
margin. This network creates a low frequency zero and high frequency pole at
(5)
(6)
The frequency of the pole is determined by C1 and paralleled resistance of R1 and R2. For high output voltage,
R1 is much bigger than R2. So
(7)
The loop gains more phase margin from this network when (Fz+Fp)/2 is placed right at crossover frequency,
which is approximately 15kHz with recommended L and C. The typical value for the zero frequency is between
1kHz to 10KHz. For high output voltage, the zero and pole are further apart which makes the feed forward
capacitor very effective. For low output voltage, the benefit of the feed forward capacitor is less visible.
gives the typical R1, R2 and the feed forward capacitor values at the certain output voltage. However, the
transient response is not greatly improved which implies that the zero frequency is too high or low to increase the
phase margin.
Table 2. Recommended Feed Forward Capacitor
Values With Different Output Voltage
C1(Feed
Output Voltage
R1
R2
Forward)
12V
437k
Ω
49.9k
Ω
33pF
16V
600k
Ω
49.9k
Ω
42pF
20V
762k
Ω
49.9k
Ω
56pF
25V
582k
Ω
30.1k
Ω
120pF
Copyright © 2006–2013, Texas Instruments Incorporated
13
Product Folder Links: