Texas Instruments LMK00304 Evaluation Board LMK00304EVM/NOPB LMK00304EVM/NOPB Hoja De Datos

Los códigos de productos
LMK00304EVM/NOPB
Descargar
Página de 22
 
 
 
 
 
LM
K00304EVM User’s Guide   
 
 
 
 
 
            
 
                March 2012 
4. 
Quick Setup 
To quickly set up and operate the board with basic equipment, refer to the setup procedure below and test 
setup shown in 
 
LMK0030x 
EVALUATION
MODULE
C
L
K
in
X
C
L
K
in
X
*
VCC_EXT
GND
Bank A Outputs
(LVPECL default)
R
E
F
o
u
(L
V
C
M
O
S
)
Bank B Outputs
(LVPECL default)
Bottom side: 
25 MHz Crystal 
(Default Input)
CLKoutBn
CLKoutBn*
CLKoutAn
CLKoutAn*
 
O-SCOPE
(50
W
 inputs)
50
W
 TERM
50
W
 TERM
Note: Terminate unused 
output traces (or disconnect 
from output pin on PCB)
CLOCK 
SOURCE
(OPTIONAL)
5
0
W
 T
E
R
M
 
4-6 V
GND
POWER 
SUPPLY
Figure 2: LMK00304 Evaluation Board Quick Start Setup 
 
1.  Verify the output mode control switches, S1[3:5], match the states shown i
 to reflect the default 
output clock interfaces configured on the EVM. 
Table 1: Default Clock Output Modes 
SW Position/Name 
SW State 
Default Clock Output Modes 
S1[3] / CLKout_Type1 
OFF 
Output Banks  
A & B are LVPECL 
S1[4] / CLKout_Type0 
OFF 
S1[5] / REFout_EN 
ON 
REFout (CMOS) enabled 
 
2.  Connect a 4 
– 6 V power supply to VCC_EXT and GND terminals of the power block labeled J2.  This powers 
the on-board LDO regulator to supply 3.3 V to the VCC and VCCO rails of the IC.  Both VCC & VCCO status 
LEDs should be lit green when ON. 
 
3.  Set the desired clock input using the input selection control switches, S1[6:7], per 
.  The onboard 25 
MHz crystal (Y1) can be selected, so an external clock source is not required.  A differential clock source can 
be connected to SMAs labeled CLKin0/0* or CLKin1/1*.  By default, these differential inputs are AC coupled 
and terminated near the device with 100 ohms differential.  To configure the EVM for a single-ended input, 
refer to th
 section.