Texas Instruments 2.5A, Dual-Input, Single Cell Switchmode Li-Ion Battery Charger with Power Path Evaluation Module BQ24 BQ24160EVM-742 Hoja De Datos

Los códigos de productos
BQ24160EVM-742
Descargar
Página de 25
Test Summary
Set Reset Watchdog Timer to update every 5 seconds.
Set Supply Precedence to IN if not already set.
Uncheck Disable Charging if checked.
Check Enable STAT/INT Outputs.
Set Battery Regulation Voltage to 4.20 V.
Set IN Input Current Limit to 2.5 A.
Set Charge Current to 1000 mA.
Click the READ button at the top of the window and confirm that the previous settings remain.
8. Enable PS #2 and adjust PS #2 so that the voltage measured by VM #2, across BAT and GND,
measures 3.3 V ± 50 mV.
9. Adjust the power supply so that VM #1 still reads 6 V ± 100 mV, if necessary, then
Measure on CM#2
I
CHRG
= 1000 mA ± 100 mA
Measure on CM#1
I
IN
= 700 mA ± 70 mA
10. Turn off PS #1 and PS #2.
2.4.2
Charge Voltage and Current Regulation of USB
1. Be sure to follow
steps .
2. Connect the output of Power Supply #1 (PS #1) in series with current meter (multimeter) #1 (CM #1) to
J8 and J11 or J9 (USB, GND).
3. Connect a voltage meter 1 (VM #1) across J8 or TP4 and J11 or TP8 (USB, GND).
4. Move JP5 to HI.
5. Turn on PS #1 and PS #2 if used.
6. Return JP5 to LO.
7. Software setup:
Press the READ button to obtain the current settings.
Set Write On Change to ON if not already set.
Set Reset Watchdog Timer to update every 5 seconds.
Set Supply Precedence to USB if not already set.
Uncheck Disable Charging if checked.
Check Enable STAT/INT Outputs.
Set Battery Regulation Voltage to 4.20 V.
Set USB Input Current Limit to 1500 mA.
Set Charge Current to 1000 mA.
Click the READ button at the top of the window, and confirm that the previous settings remain.
8. Enable PS #2 and adjust PS #2 so that the voltage measured by VM #2, across BAT and GND,
measures 3.3 V ± 50 mV.
9. Adjust the power supply so that VM #1 still reads 6 V ± 100 mV if necessary then
Measure on CM#2
I
CHRG
= 1000 mA ± 100 mA
Measure on CM#1
I
IN
= 700 mA ± 70 mA
10. Turn off PS #1 and PS #2.
2.4.3
Helpful hints
1. To observe the taper current as the battery voltage approaches the set regulation voltage, allow the
battery to charge or, if using BAT_Load (PR1010), slowly increase the PS #2 voltage powering
BAT_Load (PR1010). Use VM #2 across BAT and GND to measure the battery voltage seen by the IC.
2. To observe the V
INDPM
function, lower the current limit on PS #1.
3. To observe battery supplement mode, apply a resistive load across SYS and GND that is higher than
11
SLUU668 – March 2012
QFN-Packaged bq24160/161/162A/63EVM Evaluation Modules
Copyright © 2012, Texas Instruments Incorporated