Texas Instruments TPS51200 Sink Source DDR Termination Regulator TPS51200EVM TPS51200EVM Hoja De Datos

Los códigos de productos
TPS51200EVM
Descargar
Página de 20
4.3
List of Test Points
4.4
Note on Power Up and Power Down
4.4.1
Workstation
4.4.2
Power Up
Test Setup
www.ti.com
lists the functions of each test point.
Table 3. Test Points
TEST POINTS
NAME
DESCRIPTION
TP1
V
IN
+
3.3V or 2.5V input
TP2
GND
GND for V
IN
and VDDQ measurement
TP3
VDDQ
VDDQ input 1.2 V to 2.5 V
TP4
VLDOIN
VLDOIN input 1.2 V to 2.5 V
TP5
GND
GND for VLDOIN measurement
TP6
GND
GND for VTT measurement
TP7
VTT
VTT output
TP8
PGOOD
Monitors power good signal
TP9
ENABLE
Monitors enable signal
TP10
CHB
Input B for loop analysis, See section 6.5
TP11
CHA
Input A for loop analysis, See section 6.5
TP12
GND
GND for PGOOD and ENABLE measurement
TP13
5VIN
5-V input for transient load
TP14
GND
GND for loop measurement
TP15
CLK_IN
Monitor the load transient timing
TP16
GND
GND for 5VIN measurement
TP17
GND
GND for CLK_IN signal measurement
TP18
VTTREF
VTTREF output
TP19
GND
GND for VTTREF measurement
The following steps are guidelines for power up and power down of the EVM. Never walk away from a
powered EVM.
An ESD workstation is recommended. Make sure that an ionizer is on. Any wrist straps, boot straps or
mats must connect the user to earth ground before the EVM is removed from the protective packaging
and power is applied to it. Electrostatic smock and safety glasses should also be worn.
1. Prior to connecting the DC input source, limit the source current and then connect the DC source to
EVM as shown in
Set DC source 1 source current limit to 1 A.
Set DC source 2 source current limit to 1 A.
Set DC source 3 source current limit to 10 A.
Set DC source 4 source current limit to 1 A.
2. Connect voltage meter (V1, V2, V3, V4, V5, V6) as shown in
3. For operation with load, connect Load 1 and Load 2 to EVM as shown in
a. Connect Load 1 to J5 and Load 2 to J4
b. Set electronic load to constant current mode with initial value of 0 A.
4. Power on the DC source 1.
5. Power on the DC source 2.
6. Power on the DC source 3.
Using theTPS51200 EVM Sink/Source DDR Termination Regulator
8
SLUU323 – JUNE 2008