Installation and Operation
© 2012 Microchip Technology Inc.
DS52057A-page 13
FIGURE 2-1:
SPI TERMINAL UTILITY WINDOW
After the application is started, the state of the connection with the MCP2210 is shown 
in the Status Messages bar (in the lower left corner of the screen).
The user can establish the GP configuration. The GPs can be used as chip select pins. 
Each GP Active and Idle value can be established by selecting the appropriate check-
boxes, or by directly supplying the correct value in the GP Direct Settings section. The 
same behavior applies to the GP designation (the GP designation can be established 
by clicking the appropriate radio-button, or by directly supplying the GP designation 
value in the GP settings Direct Values section).
The SPI settings pertaining to the needed SPI transfer can be established in the SPI 
Parameters section.
The data to be sent out is filled in the Tx Data field. To send the data to the SPI slave 
device, press the SPI Transfer Data button on the lower right area of the screen. The 
data received from the SPI slave device is displayed in the Rx Data field.
The user data can be supplied in either HEX or Decimal mode. This can be 
accomplished by selecting the HEX mode checkbox. The data in the Tx and Rx Data 
fields will be displayed in HEX or Decimal.