Juniper EX 3200 EX3200-24P Hoja De Datos

Los códigos de productos
EX3200-24P
Descargar
Página de 12
5
Physical Specifications
•  Uplink module options:
 
- 4-port GbE module with pluggable SFP optics
 
- 2-port 10 GbE module with pluggable XFP optics
 
- Dual-mode 2-port 10 GbE SFP+ / 4-port GbE SFP module 
with pluggable SFP+/SFP optics
Power Options
•  AC power supplies:  Autosensing 100-120 V / 200-240 V; AC 
320 W, 600 W and 930 W
•  DC power supply:  190 W DC, input voltage range 36 V - 72 V, 
dual input feed
•  Field replaceable
Dimensions (W x H x D)
•  17.4
1
 x 1.7
2
 x 16.4
3
 in (44.21 x 4.32 x 41.73 cm)
1
 Desktop installation width noted above, rack-mount width is
  17.5 in (44.5 cm) 
2
 Height:  1 RU
3
 Depth with 320 W AC PSU and 190 W DC PSU noted above,
  18.8 in (47.8 cm) with 600/930 W AC PSU
System Weight
•  EX3200-24T with 320 W AC PSU: 14.9 lb (6.8 kg)
•  EX3200-24P with 600 W AC PSU: 15.7 lb (7.1 kg)
•  EX3200-48T with 320 W AC PSU: 15.7 lb (7.1 kg)
•  EX3200-48P with 930 W AC PSU:  16.8 lb (7.6 kg)
•  EX3200-24T-DC with 190 W DC PSU: 14.9 lb (6.8 kg)
•  EX3200-48T-DC with 190 W DC PSU: 15.7 lb (7.1 kg)
Environmental Ranges
•  Operating temperature: 32° to 113° F (0° to 45° C)
•  Storage temperature: -40° to 158° F (-40° to 70° C)
•  Operating altitude: up to 10,000 ft (3,048 m) 
•  Non-operating altitude: up to 16,000 ft (4,877 m)
•  Relative humidity operating: 10% to 85% (non-condensing) 
•  Relative humidity non-operating: 0% to 95% (non-condensing)
Cooling
•  Field-replaceable fan tray
•  Airflow: 23.5 cfm
Hardware Specifications
•  Switching Engine Model: Store and forward
•  DRAM – 512 MB
•  Flash – 1 GB
•  CPU – 600 MHz PowerPC CPU
•  GbE port density per system
 
- 24P/24T: 24 (24 host ports or 20 host ports + four-port  
GbE uplink module)
 
- 48P/48T: 48 (48 host ports or 44 host ports + four-port  
GbE uplink module)
•  10 GbE port density per system (all models): 
2 (XFP or SFP+ uplink module)
Optics
•  100 Mbps optic/connector type: LC SFP fiber supporting 
100BASE-FX SFP (multimode), LX (single-mode) and  
BX (single-strand)
•  10/100/1000BASE-T connector type: RJ-45
•  GbE SFP optic/connector type: RJ-45 or LC SFP fiber supporting 
1000BASE-T SFP, SX (multimode), LX (single-mode) or LH/ZX 
(single-mode)
•  10 GbE XFP optic/connector type: 10GE XFP LC connector,  
SR (multimode), LR (single-mode), ER (single-mode) or  
ZR (single-mode)
•  10 GbE SFP+ optic/connector type: 10GE SFP+ LC connector, SR 
(multimode), LR (single-mode) and LRM (multimode)
Physical Layer
•  Physical port redundancy: Redundant trunk group (RTG)
•  Time Domain Reflectometry (TDR) for detecting cable breaks 
and shorts
•  Auto MDI/MDIX support
•  Port speed downshift/setting max advertised speed on 
10/100/1000BASE-T ports
Packet Switching Capacities
•  24P/24T: 88 Gbps
•  48P/48T: 136 Gbps
Layer 2 Throughput (Mpps)
•  24P/24T: 65 Mpps (wire speed)
•  48P/48T: 101 Mpps (wire speed)
EX3200 Specifications