Chauvin Arnoux C.A 5231+ Zange mini 03 Digital-Multimeter, DMM, P01196734 Hoja De Datos

Los códigos de productos
P01196734
Descargar
Página de 117
English 
43 - 117 
4.2.5 
Continuity test 
Range 
Resolution 
Uncertainty 
Measurement 
current 
600 
Ω
 
0,1 
Ω
 
Audible signal 
triggered  
< 100 
Ω
 ± 3 
Ω
 
< 0,35 mA 
4.2.6 
Diode test 
Range 
Resolution 
Uncertainty 
(
±
Open-circuit 
voltages 
Measurement 
current 
2,8 V 
0,001 V 
1 % + 2 cts 
< 2,8 V 
< 0,9 mA 
4.2.7 
AC/DC Current 

 
600 A AC or DC with clamp having a ratio of 1 mV / 1 A 
 
Range 
Resolution 
Uncertainty (
±
600 A 
0,1 A 
40 Hz to 1 kHz 
2,0 % + 2 cts  
(note 1) 
 
Note 1 : not including the uncertainty due to the current clamp 
sensor 
4.3 ENVIRONMENTAL CONDITIONS 
Environmental conditions 
In use 
In storage 
Temperature : 
0 °C to +50 °C 
-20 °C to +70 °C 
Relative humidity (HR) : 
<=90% at 40°C 
<=50 % at 60  °C 
4.4 CHARACTERISTICS OF CONSTRUCTION 
Dimension : 
H 155 x L 75 x P 55 mm 
Weight : 
320 g (with the battery) 
Measurement 
acquisition : 
3 times per second 
Bargraph : 
61 segments, refresh interval 30ms