MODEL 2831E SPECIFICATIONS 
DC Voltage 
Resolution, Full Scale reading and Accuracy: ± (% of reading + % of range), 23 °C ± 5 °C 
Rate 
Range 
Resolution 
Full Scale 
Reading 
Accuracy   
(1 year) 
Typical 
Input 
Impedance 
 
 
Slow 
 
 
200.00 mV 
2.0000 V 
20.000 V 
200.00 V 
1000.0 V 
10 
μV 
100 
μV 
1 mV 
10 mV 
100 mV 
210.00 
2.1000 
21.000 
210.00 
1010.0 
(2) 
0.03%+0.08% 
(1) 
0.03%+0.05% 
(1) 
0.03%+0.06% 
0.03%+0.06% 
0.03%+0.06% 
>10 M
Ω
 
>11.1 M
Ω
 
>10.1 M
Ω
 
10 M
Ω
 
10 M
Ω
 
 
(1)
   under REL status 
 
(2)
   1% over-range (1010 V) is readable at 1000 V range 
Maximum input voltage: 1000 VDC or peak ac for all ranges. 
 
   
AC Voltage 
Resolution, Full Scale reading and Accuracy 
Range 
Resolution 
Full Scale Reading 
200.00 mV 
2.0000 V 
20.000 V 
200.00 V 
750.0 V 
10 μV 
100 μV 
1 mV 
10 mV 
100 mV 
210.00 
2.1000 
21.000 
210.00 
757.5
(1) 
(1)
   1% over-range (757.50V) is readable at 750V range 
 
ACCURACY: ± (% of reading + % of range), 23 °C ± 5 °C 
Rate 
Range 
Accuracy(1 year)
 (1)
  23 °C ± 5 °C
 
20-50 Hz 
50-20 kHz 
20-50 kHz 
50-100 kHz 
 
 
Slow 
 
200.00 mV 
2.0000 V 
20.000 V 
200.00 V 
750.0 V   
1.0%+0.2% 
1.0%+0.2% 
1.0%+0.2% 
------ 
------
 
0.5%+0.15% 
0.4%+0.05% 
0.4%+0.05% 
0.8%+0.075% 
0.8%+0.075% 
1.8%+0.25% 
1.5%+0.1% 
1.5%+0.1% 
1.5%+0.1% 
  1.5%+0.1% 
(2)
 
3.0%+0.75% 
3.0%+0.25% 
3.0%+0.25% 
3.0%+0.25% 
3.0%+0.25% 
(2)
 
(1)
  Specifications are for sine wave inputs >5% of range.
 
(2)   
Limit at 40 kHz or 
≤ 3×10
7
 Volt-Hz for 750 V range   
Measurement method: True RMS measurement 
Maximum Crest factor: 3.0 at full scale 
Maximum input voltage: 750 Vrms 
≤ 3×10
7
 Volt-Hz for all ranges 
Input impedance: 1 
MΩ ± 2% in parallel with capacitance <100 pF 