Chapter 10 Analog-to-Digital Converter (S08ADC12V1)
MC9S08DZ60 Series Data Sheet, Rev. 4
190
Freescale Semiconductor
When a conversion is aborted, the contents of the data registers, ADCRH and ADCRL, are not altered.
However, they continue to be the values transferred after the completion of the last successful conversion.
If the conversion was aborted by a reset, ADCRH and ADCRL return to their reset states.
10.4.4.4
Power Control
The ADC module remains in its idle state until a conversion is initiated. If ADACK is selected as the
conversion clock source, the ADACK clock generator is also enabled.
Power consumption when active can be reduced by setting ADLPC. This results in a lower maximum value
for f
ADCK
(see the electrical specifications).
10.4.4.5
Sample Time and Total Conversion Time
The total conversion time depends on the sample time (as determined by ADLSMP), the MCU bus
frequency, the conversion mode (8-bit, 10-bit or 12-bit), and the frequency of the conversion clock (
f
ADCK
).
After the module becomes active, sampling of the input begins. ADLSMP selects between short (3.5
ADCK cycles) and long (23.5 ADCK cycles) sample times.When sampling is complete, the converter is
isolated from the input channel and a successive approximation algorithm is performed to determine the
digital value of the analog signal. The result of the conversion is transferred to ADCRH and ADCRL upon
completion of the conversion algorithm.
If the bus frequency is less than the f
ADCK
 frequency, precise sample time for continuous conversions
cannot be guaranteed when short sample is enabled (ADLSMP=0). If the bus frequency is less than 1/11th
of the f
ADCK
frequency, precise sample time for continuous conversions cannot be guaranteed when long
sample is enabled (ADLSMP=1).
The maximum total conversion time for different conditions is summarized in
.
Table 10-13. Total Conversion Time vs. Control Conditions
Conversion Type
ADICLK
ADLSMP
Max Total Conversion Time
Single or first continuous 8-bit
0x, 10
0
20 ADCK cycles + 5 bus clock cycles
Single or first continuous 10-bit or 12-bit
0x, 10
0
23 ADCK cycles + 5 bus clock cycles
Single or first continuous 8-bit
0x, 10
1
40 ADCK cycles + 5 bus clock cycles
Single or first continuous 10-bit or 12-bit
0x, 10
1
43 ADCK cycles + 5 bus clock cycles
Single or first continuous 8-bit
11
0
5
μ
s + 20 ADCK + 5 bus clock cycles
Single or first continuous 10-bit or 12-bit
11
0
5
μ
s + 23 ADCK + 5 bus clock cycles
Single or first continuous 8-bit
11
1
5
μ
s + 40 ADCK + 5 bus clock cycles
Single or first continuous 10-bit or 12-bit
11
1
5
μ
s + 43 ADCK + 5 bus clock cycles
Subsequent continuous 8-bit;
f
BUS
>
 f
ADCK
xx
0
17 ADCK cycles
Subsequent continuous 10-bit or 12-bit;
f
BUS
>
 f
ADCK
xx
0
20 ADCK cycles
Subsequent continuous 8-bit;
f
BUS
>
 f
ADCK
/11
xx
1
37 ADCK cycles