Specification: 
OXY 3690 MP 
OXY 3690 S MP
 
Display range: 
0,0 - 100,0 % air oxygen 
0,0 - 100,0 % air oxygen 
Rec. sensor meas. range: 
0,0 - 100,0 % air oxygen 
0,0 - 25,0 % air oxygen
 
Sensor name: 
(Standard)
 
GGO 370 / MU  
GGO 369 S / MU
 
Sensor type: 
electrochemical partial oxygen pressure sensor   
electrochemical partial oxygen pressure sensor 
Meas. range O
2
-Concentration:  0,0 ... 100,0 % O
2
  (gaseous) 
0,0 ... 25,0 % O
2
  (gaseous) 
Electrolyte: 
basic 
acid 
Response time: 
90% at <10sec., depending on temperature  90% at <15sec., depending on temperature 
Linearity: 
<   2
 
%
 
O
2
 
± 0.1 % O
± 0.1 % O
2
 
< 25
 
%
 
O
± 0.5 % O
2
  
± 0.5 % O
2
 
> 25
 
%
 
O
± 1.0 % O
2
  
not specified 
Cross sensitivities: 
signal of <0.1 % O
2
 at
 
signal of <0.002 % O
2
 at:
 
 
15% CO
2
 
in N
2
, 10% CO
 
in N
2
, 3000ppm NO in N
2
,   100% CO
2
, 100% CO, 3000ppm NO in N
2
,  
3000ppm C
3
H
8
 in N
2
, 500ppm H
2
S
 
in N
2
 
,  
1000ppm H
2
 in N
2
 
, 100% C
3
H
8
, 2000ppm H
2
S
 
in N
2
,  
1000ppm Benzene in N
2000ppm SO
2
 in N
2
, 1000ppm Benzene in N
Operating pressure: 
0.5 to 2.0 bar absolute (at one-sided strain: max. 0.25 bar over-/under-pressure) 
Warranty period: 
12 months 
(
assuming appropriate usage according to the manual) 
Nominal sensor life: 
approx. 2 years at nominal condition 
Temperature compensation:   integrated in oxygen sensor 
Sensor connection:   
5-pole screwable socket 
Device accuracy:  
Display 
±0,1% oxygen ±1digit  (adjusted device, at nominal temperature = 25°C) 
add. output signal: 
±0,2 % FS 
Output signal: 
refer to type plate 
Connection: 
4 - 20 mA  (2-wire) 
Voltage     (3- or 4-wire) 
Auxiliary energy: 
(
supply voltage
)
  Uv = 12 - 30 V DC (4-20mA) 
Uv = 18 - 30 V DC (0-10V)   
or refer to type plate 
Electric isolation: 
input electrically isolated 
Reverse voltage protection: 50V permanent 
Perm. impedance 
(at 4-20mA)
:    R
A
(Ohm) < ( (Uv - 12V) / 0.02A ) 
Example: for Uv = 18V: 
R
A
 < (18V - 12V) / 0.02A     =>   R
A
 < 300 Ohm
 
Permissible load 
(at 0-...V)
:    R
L
(Ohm) > 3000 Ohm 
Display:   
approx. 10 mm high, 4-digit LCD-display 
Working conditions: 
0 to 45°C, 0 to 95 %RH  (non-condensing)  
Storage temperature: 
-20 to 70°C  (sensor: -15 to 50°C) 
Housing: 
ABS (IP65 - with the exception of sensor and temperature probe connection sockets) 
Dimensions: 
82 x 80 x 55 mm (without elbow-type plug and sensor sockets) 
Mounting: 
with fixing holes for wall mounting (in housing - 
accessible after cover has been removed
)
 
Mounting distance: 
50 x 70mm, max. shaft diameter of mounting screws is 4 mm. 
Sensor dimensions:   
GGO369..: approx. Ø 36 mm x 95 mm (150 mm incl. anti-buckling glanding),  
GOO369..: approx. Ø 40 mm x 105 mm (160 mm incl. anti-buckling glanding) 
Housing with M16 x 1-screw thread 
(sensor can be connected to line tubes by means of an additional adapter
)
 
Electric connection: 
elbow-type plug conforming to DIN 43650 (IP65), 
max. wire cross section: 1.5 mm², wire/cable diameter from 4.5 to 7 mm 
EMC: 
The device corresponds to the essential protection ratings established in the Regulations of the 
Council for the Approximation of Legislation for the member countries regarding electromagnetic 
compatibility (89/336/EWG). In accordance with EN50081-1 and EN50082-1 
Additional error: <1%