miniLAB 1008 User's Guide  
Functional 
Details 
Since the analog inputs are restricted to a −10 V to +20 V signal swing with respect to 
ground, all ranges except ±20 V can realize a linear output for any differential signal 
with zero common mode voltage and full scale signal inputs. The ±20 V range is the 
exception. You cannot put −20 V on CHHI, and 0 V on CHLO, since this violates the 
input range criteria. Table 4-3 shows some possible inputs and the expected results. 
Table 4-3. Sample Inputs and Differential Results 
CHHI CHLO Result 
-20 V 
0 V 
Invalid 
-15 V 
+5 V 
Invalid 
-10 V 
0 V 
-10 V 
-10 V 
+10 V 
-20 V 
0 V 
+10 V 
-10 V 
0 V 
+20 V 
-20 V 
+10 V 
-10 V 
+20 V 
+10 V 
0 V 
+15 V 
-5 V 
+20 V 
+20 V 
+20 V 
 
Additional information on analog signal connections 
For general information regarding single-ended and differential inputs, refer to the 
Guide to Signal Connections (available on our web site at 
Digital I/O terminals (DIO0 - DIO3) 
Connect up to four digital I/O lines to the screw terminals containing pins DIO0 to 
DIO3. Refer to th
 on page 4-6 for the location of these pins. You can 
configure each digital channel independently for either input or output.  
Overvoltage/short circuit protection is provided with a 1.5 k
Ω series resistor on each I/O 
pin. Use of the resistor may limit the value of the output current, however. For example, 
if the output current is 1 mA, the resistor drops 1.5 V, resulting in an output of 3.5 V. 
You can use the digital I/O terminals to detect the state of any TTL level input. In Figure 
4-8, if the switch is set to the +5 V input, and the DIO0 reads TRUE (1). If the switch is 
moved to GND, the DIO0 reads FALSE. 
4-10