the battery) in ampere*hours (A*hrs) of the battery is calculated and displayed.  To run a battery test, 
follow these steps:
Key presses
Display
I-set, enter current value with 
numerical keys, then press 
Enter.
Set the DC Load to constant current mode and set the 
current you want to draw from the battery.  (You may have 
to press the I-set key twice to be able to set the current 
value.) 
Shift + Battery
MIN VOLT= 0.10V
  This indicates you're being asked for the 
voltage level where the battery test will be over.
Enter voltage level and press 
Enter.
When you press Enter, the test will start.  The 
CC 
annunciator will be on.
△ or ▽
Shows  the power level and the ampere*hours (A*hrs) 
accumulated so far.
When the battery voltage drops below the specified value, the test will turn off and you will see 
the 
OFF 
annunciator.
△ or ▽
Display the total charge delivered by the battery in 
ampere*hours (A*hrs).
Shift + Battery
Turns battery testing mode off.
NOTE:  you must make sure that you press Shift + Battery at the end of the test.  Otherwise, the 
instrument will not respond to any key presses except 
△ or ▽.
Transient operation
The transient condition allows switching between two different load values.  There are three different 
types of transient operation.
Continuous transient operation
In continuous transient operation, the load is continuously switched between two load values.  An 
example is shown in the following figure:
10A
5A
Continuous Transient Operation
2.0ms
3.0ms
Note that this transient behavior works with any of the operation modes CC, CV, CW, or CR.  Here 
are the keystrokes used to setup this continuous transient condition:
Keys
Display
I-set
Standard display of voltage and current (or, you'll be asked to enter a 
current value).
8500 DC Load Series                    
Version:  September 2, 2009 
Page 33 of 76