Gw Instek PEL-3111 Electronic Load PEL-3111 Hoja De Datos

Los códigos de productos
PEL-3111
Descargar
Página de 174
 
 
COMMNAND OVERVIEW 
77 
:CURRent:FREQuency 
Set
Query
 
 
Description 
Sets the CC dynamic mode switching frequency. 
This command along with the “:CURRent:DUTY” 
command is used when the dynamic time setting 
is set to “Freq./Duty”. 
This command is only applicable for dynamic 
mode. 
Syntax 
:CURRent:FREQuency {<NRf> | MINimum | 
MAXimum} 
Query Syntax 
:CURRent:FREQuency? 
Related 
Commands 
:CURRent:DUTY 
Parameter  
<NRf> 
Sets the switching 
frequency in hertz. 
 
MINIMUM or MIN 
Minimum frequency 
 
MAXIMUM or MAX 
Maximum frequency 
Return parameter  <NR2> 
Returns the frequency in 
hertz. 
Example 
:CURRent:FREQuency 60 
Sets frequency to 60Hz. 
Query example 
:CURRent:FREQuency? 
>60 
Returns the switching frequency (60Hz). 
:CURRent:DUTY 
Set
Query
 
 
Description 
Sets the positive duty cycle for the CC dynamic 
mode switching frequency. This command along 
with the “:CURRent:FREQuency” command is 
used when the dynamic time setting is set to 
“Freq./Duty”. 
This command is only applicable for dynamic 
mode.