Gw Instek PEL-3021 Electronic Load PEL-3021 Hoja De Datos

Los códigos de productos
PEL-3021
Descargar
Página de 174
 
 
PEL-3000 Programming Manual 
142
 
:STATus:QUEStionable:ENABle 
Set
Query
 
 
Description 
Sets which events are enabled in the Questionable 
Status Enable register. The mask values are the bit 
weights of the events. See page 154 for details. 
Syntax 
:STATus:QUEStionable:ENABle <NR1> 
Query Syntax 
:STATus:QUEStionable:ENABle? 
Parameter/ 
Return Parameter 
<NR1>  Condition  
<NR1> 
Condition 
OV 
512 
UV 
 
OC 
1024  
EXT 
 
OP 
2048  
REV 
 
16 
OT 
All other 
bits 
Not used 
Example 
:STATus:QUEStionable:ENABle 11 
Events OV, OC and OP (Bits 1, 2, 3) are enabled in the 
Questionable Status Enable register.        
Query example 
:STATus:QUEStionable:ENABle? 
>11 
Indicates that OV, OC and OP bits are enabled in the 
Questionable Status Enable register. 
:STATus:QUEStionable[:EVENt]? 
Set
Query
 
 
Description 
Returns the status of the Questionable Status Event 
register. The register is cleared upon reading. See 
page 154 for details. 
Query Syntax 
:STATus:QUEStionable[:EVENt]? 
Return parameter  <NR1>  Condition  
<NR1> 
Condition 
 
OV 
512 
UV 
 
OC 
1024  
EXT 
 
OP 
2048  
REV 
 
16 
OT 
All other 
bits 
Not used