PEL-3000 User Manual
60
Note
The load can be set to automatically turn on at
start up. See page 75.
start up. See page 75.
The load can be turned on via remote control.
See the programming manual.
See the programming manual.
The load can be turned on via external control.
See page 143.
See page 143.
By default the load will automatically turn off if
the range or operating mode (CC, CV, CR, CP) is
changed. To disable this behavior, Set Load Off
(Mode) and Load Off (Range) to the OFF setting.
See page 76 for details.
the range or operating mode (CC, CV, CR, CP) is
changed. To disable this behavior, Set Load Off
(Mode) and Load Off (Range) to the OFF setting.
See page 76 for details.
Display
Mode
CP
IRange
H 35A
VRange
L 15V
Function
Dynamic
Configure
1.500
V
0.000
A
1.50
w
Timer1
0.025
Level2
0.00
Level1
0.00
LOAD
RS232
Fine
03/Sep/2012
mS
W
W
LOAD on
Shorting the Load
Description
The Short key can be used to simulate a short
circuit of the load input terminals. A short
circuit is simulated by:
circuit of the load input terminals. A short
circuit is simulated by:
Setting the current to the maximum value in CC
mode.
mode.
Setting the resistance to the minimum value in
CR mode.
CR mode.
Setting the voltage to the minimum value in CV
mode.
mode.
Setting the power to the maximum value in CP
mode.
mode.
When the load is shorted, the external controller
also sends a short signal. See page 149 for usage
details.
also sends a short signal. See page 149 for usage
details.