Gw Instek PEL-3021 Electronic Load PEL-3021 Hoja De Datos
Los códigos de productos
PEL-3021
OPERATION
71
Von Voltage Settings
Von Voltage Level
Description
The Von Voltage is the threshold voltage at
which the load module will start to sink
current.
which the load module will start to sink
current.
Time
Von voltage
Von
V
Time
I
PEL-3000
V out
Load on
Operation
1. Press
Main
> Configure[F5] > Other[F2] and
set the Von Voltage level.
Range:
Von Voltage: 0.00~rating voltage