Hengstler Tico-MFH- 10-30VDC, R2,TR, RS232 CR0774402 Hoja De Datos

Los códigos de productos
CR0774402
Descargar
Página de 7
Data sheet tico 772/773/774 
19/07/2012
All rights reserved
Page 4 of 7 
Multifunctional counter  tico 772/773/774
tico 772/773/774
PHYSICAL DATA
Accuracy 
Time base: 
±  30 ppm 
of the timer 
Start/Stop-point in time:  16 µs/16 ms (not damped/damped) 
 
Resolution: 
100 µs = 100 ppm
Overall tolerance 
= Displayed resolution + tolerance of timebase = 130 ppm
 
 
 
Safety provisions
 
EN 61 010-1/IEC 61010-1
Protection class 
II; EN 61010-1/IEC 61010-1
Pollution degree 
V 2, EN 50178
EMC interference 
EN 61326-1 industrial environment** 
compatibility
EMC emissions 
EN 61326-1 Class B**
Ambient temperature  0°-50°C  EN 60 068-2-1/2
Storage temperature  -20° to +65°C EN 60 068-2-1/2
Climate 
40°C/93% rel. humidy class 4K4H,  EN 60 068-2-78 
 
25-50°C/93% rel. humidity cyclical,  EN 60 068-2-38
Ingress protection 
IP 65 front; EN 60529 
 
IP 20 terminals
Vibration resistance  10 m/s² (10 to 150 Hz); IEC 60 068-2-6
Shock resistance 
100 m/s² (18 ms); IEC 60 068-2-27
Resistance 
Front film to DIN 42 115-2 
to chemicals
Approvals 
UL, CSA (pending)
RoHS Compliant
 
 
 
Installation 
Front-panel installation with tenter (frame) 
 
Front panel thickness max. 11 mm
Dimensions 
In accordance with DIN 43700, 48 mm x 48 mm x 118 mm, 
 
installation depth 110 mm 
 
Front-panel cutout 
45 mm x 45 mm + 0.3 mm
Weight 
Approx. 200 g
 
**  For cable lengths >30 m, connection to DC supply and input level TTL, 
  additional protective circuits will be necessary.
ENVIRONMENTAL REGULATIONS,  
SAFETY PROVISIONS