Analog Devices ADP5024 Evaluation Board ADP5024CP-EVALZ ADP5024CP-EVALZ Hoja De Datos

Los códigos de productos
ADP5024CP-EVALZ
Descargar
Página de 28
Data Sheet 
ADP5024 
 
Rev. E | Page 5 of 28 
LDO SPECIFICATIONS 
V
IN3
 = (V
OUT3
 + 0.5 V) or 1.7 V (whichever is greater) to 5.5 V; C
IN
 = C
OUT
 = 1 µF; T
J
 = −40°C to +125°C for minimum/maximum 
specifications, and T
A
 = 25°C for typical specifications, unless otherwise noted.
Table 4.  
Parameter  
Symbol 
Test Conditions/Comments 
Min 
Typ 
Max 
Unit 
INPUT VOLTAGE RANGE 
V
IN3
 
 
1.7 
 
5.5 
OPERATING SUPPLY CURRENT   
 
 
 
 
 
Bias Current per LDO
I
VIN3BIAS
 
I
OUT3
 = 0 µA 
 
10 
30 
µA 
 
 
I
OUT3
 = 10 mA 
 
60 
100 
µA 
 
 
I
OUT3
 = 300 mA 
 
165 
245 
µA 
Total  System Input Current 
I
IN
 
Includes all current into AVIN, VIN1, 
VIN2, and VIN3 
 
 
 
 
LDO Only 
 
I
OUT3
 = 0 µA, all other channels 
disabled  
  
53 
 
µA 
OUTPUT CHARACTERISTICS 
 
 
 
 
 
 
Output Voltage Accuracy 
ΔV
OUT3
/V
OUT3
 
100 µA  < I
OUT3
 < 300 mA 
−1.8 
 
+1.8 
Line Regulation 
(ΔV
OUT3
/V
OUT3
)/ΔV
IN3
 
I
OUT3
 = 1 mA 
−0.03 
 
+0.03 
%/V 
Load Regulation
(ΔV
OUT3
/V
OUT3
)/ΔI
OUT3
 
I
OUT3
 = 1 mA to 300 mA 
 
0.001 
0.003 
%/mA 
VOLTAGE FEEDBACK 
V
FB3
 
 
0.491 
0.5 
0.509 
DROPOUT VOLTAGE
V
DROPOUT
 
V
OUT3
 = 5.2 V, I
OUT3
 = 300 mA 
 
50 
 
mV 
 
 
V
OUT3
 = 3.3 V,  I
OUT3
 = 300 mA 
 
75 
140 
 
 
 
V
OUT3
 = 2.5 V,  I
OUT3
 = 300 mA 
 
100 
 
mV 
 
 
V
OUT3
 = 1.8 V,  I
OUT3
 = 300 mA 
 
180 
 
mV 
CURRENT-LIMIT THRESHOLD
I
LIMIT3
 
 
335 
600 
 
mA 
ACTIVE PULL-DOWN 
R
PDWN-L
 
Channel disabled 
 
600 
 
Ω 
OUTPUT NOISE 
 
 
 
 
 
 
Regulator LDO  
NOISE
LDO
 
10 Hz to 100 kHz, V
IN3
 = 5 V, V
OUT3
 = 2.8 V 
 
100 
 
µV rms 
POWER SUPPLY REJECTION 
RATIO  
PSRR 
 
 
 
 
 
Regulator LDO 
 
10 kHz, V
IN3
 = 3.3 V,  V
OUT3
 = 2.8 V,   
I
OUT3
 = 1 mA 
 
60 
 
dB 
 
 
100 kHz, V
IN3
 = 3.3 V, V
OUT3
 = 2.8 V,  
I
OUT3
 = 1 mA 
 
62 
 
dB 
 
 
1 MHz, V
IN3
 =  3.3 V, V
OUT3
 = 2.8 V,   
I
OUT3
 = 1 mA 
 
63 
 
dB 
 
1
 All limits at temperature extremes are guaranteed via correlation using standard statistical quality control (SQC). 
2
 This is the input current into VIN3, which is not delivered to the output load. 
3
 Based on an endpoint calculation using 1 mA and 300 mA loads. 
4
 Dropout voltage is defined as the input-to-output voltage differential when the input voltage is set to the nominal output voltage. This applies only to output voltages 
above 1.7 V. 
5
 Current-limit threshold is defined as the current at which the output voltage drops to 90% of the specified typical value. For example, the current limit for a 3.0 V 
output voltage is defined as the current that causes the output voltage to drop to 90% of 3.0 V or 2.7 V.