Analog Devices AD9714 Evaluation Board AD9714-DPG2-EBZ AD9714-DPG2-EBZ Hoja De Datos

Los códigos de productos
AD9714-DPG2-EBZ
Descargar
Página de 12
Evaluation Board User Guide 
UG-073
 
Rev. 0 | Page 7 of
 12 
EVALUATION BOARD SOFTWARE: QUICK START PROCEDURES 
This section provides quick start procedures for using the AD911x 
or AD971x. Both the default and optional settings are described. 
CONFIGURING THE BOARD 
Before using the software for testing, configure the evaluation 
board as follows: 
1.  Connect the evaluation board to the DPG2 evaluation 
board.  
2.  Connect the AD911x or AD971x evaluation board to the 
PC with a USB cable (ConnectorXP2 USB/BRD PWR). 
The LED XD1 should turn on. If it does not turn on, refer 
to the Power Circuitry section and configure the board 
with the default setting.  
3.  Connect a clean signal generator with low phase noise to 
provide an input signal to the clock distribution source 
input, J10. Use a 1 m, shielded, RG-58, 50 Ω coaxial cable 
to connect the signal generator. 
USING THE SOFTWARE FOR TESTING 
Set Up the DPG2 Software 
After configuring the board, set up the DPG2 by following  
these steps: 
1.  Open DPGDownloader (Start > Programs > Analog 
Devices > DPG > DPGDownloader
).  
The program should automatically recognize and display 
the evaluation board, such as the AD9717 used in this 
example, in the drop-down menu for the Evaluation 
Board
, as shown in Figure 3  
2.  Select LVCMOS-3.3V (DCO) for the Port Configuration 
as the DPG2 data clock input, also shown in Figure 3
086
98
-00
3
 
Figure 3. DPG2 Board Configuration 
3.  Open the AD911x or AD971x SPI software (Start > 
Programs > Analog Devices > AD9717 > AD971x SPI
). 
4.  Select the clock dividers for the data clock going to the 
DPG2, and for the clock going to the DAC. The divider 
ratio for the DAC clock should be double the ratio for the 
data clock as shown in Figure 4
08
69
8-
00
4
 
Figure 4. AD9512 Clock Divider Setting 
 
The clock going to the DAC should be no greater than 
125 MHz. When the AD9512 configuration is complete, 
verify the clock frequency output to the DPG2 in  
Figure 3. The frequency displayed represents the frequency 
of the clock sent to the DPG2. It should be no greater than  
250 MHz. 
5.  In the DPG2 window (see Figure 5), select Add Generated 
Waveform
, and then select Single Tone. A single tone 
panel is added to the vector list. Enter a clock frequency of 
125 MHz for Data Clock Frequency.  
Note that this frequency is half of the frequency in Figure 3 
for Data Clock Frequency as the data clock sent to the 
DPG2 is twice the rate of the DAC. However, the vector 
generation is done using the DAC clock (data clock/2) (see 
Figure 4).  
6.  Make the following entries: 
•  Enter 10 MHz as the Desired Frequency of the tone.  
•  The DAC Resolution should be set at the resolution 
of the IC 
selected (14 bits for the 
 an
AD9117, 12 bits for th
 and AD9116, and  
so on).  
•  Keep Record Length at 16384 
•  The digital scaling back of the tone can be done by 
changing the Amplitude (defaults to 0 dB).  
•  Ensure that Unsigned Data and Generate Complex 
Data (I & Q)
 are selected.  
See Figure 5 for the appropriate settings.  
08698-
005
 
Figure 5. Single Tone Generation 
7.  In the lower portion of the screen, select 1I / 1Q: Single 
Tone
 as the Data Vector, choosing the appropriate in-
phase and quadrature data for the I and Q vectors, shown 
in Figure 6. The other options can be left at their default.