7 Command Sequence Example
This chapter contains examples of how to connect to the STK500 from the PC
Frontend and how to read signature from a device.
Frontend and how to read signature from a device.
7.1 Connect
The sequence of commands and parameters sent from AvrStudio to the STK500 in
order to connect is listed below.
order to connect is listed below.
• CMD_SIGN_ON
• CMD_GET_PARAMETER, PARAM_TOPCARD_DETECT
• CMD_GET_PARAMETER, PARAM_HW_VER
• CMD_GET_PARAMETER, PARAM_SW_MAJOR
• CMD_GET_PARAMETER, PARAM_SW_MINOR
• CMD_GET_PARAMETER, PARAM_TOPCARD_DETECT
• CMD_GET_PARAMETER, PARAM_HW_VER
• CMD_GET_PARAMETER, PARAM_SW_MAJOR
• CMD_GET_PARAMETER, PARAM_SW_MINOR
7.2 Read Signature
7.2.1 In System Programming
The sequence of commands and parameters sent from AvrStudio to the STK500 in
order to read the device signature through ISP is listed below. Note that one already
have to be connected to do this.
order to read the device signature through ISP is listed below. Note that one already
have to be connected to do this.
• CMD_GET_PARAMETER, PARAM_TOPCARD_DETECT
• CMD_GET_PARAMETER, PARAM_CONTROLLER_INIT
• CMD_SET_PARAMETER, PARAM_CONTROLLER_INIT
• CMD_SET_PARAMETER, PARAM_RESET_POLARITY
• CMD_ENTER_PROGMODE_ISP
• CMD_READ_SIGNATURE_ISP
• CMD_READ_SIGNATURE_ISP
• CMD_READ_SIGNATURE_ISP
• CMD_LEAVE_PROGMODE_ISP
• CMD_GET_PARAMETER, PARAM_CONTROLLER_INIT
• CMD_SET_PARAMETER, PARAM_CONTROLLER_INIT
• CMD_SET_PARAMETER, PARAM_RESET_POLARITY
• CMD_ENTER_PROGMODE_ISP
• CMD_READ_SIGNATURE_ISP
• CMD_READ_SIGNATURE_ISP
• CMD_READ_SIGNATURE_ISP
• CMD_LEAVE_PROGMODE_ISP