SAM4E [DATASHEET]
Atmel-11157D-ATARM-SAM4E16-SAM4E8-Datasheet_12-Jun-14
444
24.6
SAM-BA Monitor
The SAM-BA boot principle:
Once the communication interface is identified, to run in an infinite loop waiting for different commands as shown
in 
Mode commands:
̶
Normal mode configures SAM-BA Monitor to send/receive data in binary format
̶
Terminal mode configures SAM-BA Monitor to send/receive data in ASCII format
Write commands: Write a byte (O), a halfword (H) or a word (W) to the target 
̶
Address: Address in hexadecimal
̶
Value: Byte, halfword or word to write in hexadecimal
Read commands: Read a byte (o), a halfword (h) or a word (w) from the target
̶
Address: Address in hexadecimal
̶
Output: The byte, halfword or word read in hexadecimal
Send a file (S): Send a file to a specified address
̶
Address: Address in hexadecimal
Note:
There is a time-out on this command which is reached when the prompt ‘>’ appears before the end of the command 
execution.
Receive a file (R): Receive data into a file from a specified address
̶
Address: Address in hexadecimal
̶
NbOfBytes
: Number of bytes in hexadecimal to receive
Go (G): Jump to a specified address and execute the code
̶
Address: Address to jump in hexadecimal
Get Version (V): Return the SAM-BA boot version
Note:
In Terminal mode, when the requested command is performed, SAM-BA Monitor adds the following prompt sequence 
to its answer: <LF>+<CR>+'>'.
Table 24-2.
Commands Available through the SAM-BA Boot
Command
Action
Argument(s)
Example
N
Set Normal mode
No argument
N
T
Set Terminal mode
No argument
T#
O
Write a byte
Address, Value#
O200001,CA#
o
Read a byte
Address,#
o200001,#
H
Write a half word
Address, Value#
H200002,CAFE#
h
Read a half word
Address,#
h200002,#
W
Write a word
Address, Value#
W200000,CAFEDECA#
w
Read a word
Address,#
w200000,#
S
Send a file
Address,#
S200000,#
R
Receive a file
Address, NbOfBytes#
R200000,1234#
G
Go
Address#
G200200#
V
Display version
No argument
V#