Atmel ATSAM3U-EK Hoja De Datos

Descargar
Página de 53
Evaluation Kit Hardware
4-22
SAM3U-EK Evaluation Kit User Guide
6478E–ATARM–30-Mar-11
4.4.2
Jumpers
The SAM3U-EK board jumpers are used for many purposes such as internal Flash Memory reinitializa-
tion, power current measurement and other configurations.
PC29
PWML0
MCDA5
AD5
MCDA5
SD/MMC
PC30
PWML1
MCDA6
AD6
MCDA6
SD/MMC
PC31
PWML2
MCDA7
AD7
MCDA7
SD/MMC
Table 4-7.  PIO Port C Assignment
I/O Line
Peripheral A
Peripheral B
Extra Function
EK Usage
Device
Table 4-8.  Jumpers Setting
Designation
Label
Default Setting
Feature
JP1
ERASE
Open
Close it to reinitialize the Flash content and 
some of its NVM bits. 
This jumper must be closed for more than 
220 ms at power-up to perform the re-
initialization.
JP2 (DNP)
TEST
Not populated (open)
reserved
JP3
VIN
Close
Measure current feed into VDDIN pin
JP5
AD12BVREF
Pin1 Pin2 close, 
Switch to +3V3
Select the reference voltage of the 12-bit 
ADC to be either 3.3V (close 1-2) or 2.5V 
(close 2-3)
JP6
VIO
Close
Measure current feed into VDDIO pins
JP7
VUTMI
Close
Measure current feed into VDDUTMI pin
JP8
VANA
Close
Measure current feed into VDDANA pin
JP9
VCORE
Close
Measure current feed into VDDCORE pins
JP10
VPLL
Close
Measure current feed into VDDPLL pin
JP11
VOUT
Close
Measure current out of VDDOUT pin
JP12
NCS0
Close
Disconnection possibility on NCS0
JP13
NCS1
Close
Disconnection possibility on NCS1
JP14
NCS2
Close
Disconnection possibility on NCS2
JP15
3AXS
Close
G-select feature, sensitivity level switch. 
Close as 440mv/g, open as 117.5mV/g
JP16
3AXS
Close
Open to cause a slight deflect on each axis 
output, which is device self test
JP17
FORCE POWER ON
Close
Force +3V3 LDO output valid
JP18 (DNP)
-
Not populated (open)
Close to enable 50-Ohm terminal resistor for 
AD12BAD3 BNC port
JP19 (DNP)
-
Not populated (open)
Close to enable 50-Ohm terminal resistor for 
AD0 BNC port
JP20
ADVREF
Pin1 Pin2 close, 
Switch to +3V3
Select the reference voltage of the 10-bit 
ADC to be either 3.3V (close 1-2) or 2.5V 
(close 2-3)
JP21
-
Open
Measure current feed into ZigBee module