6355F–ATARM–12-Mar-13
 
31.7.5.3
IrDA Demodulator
The demodulator is based on the IrDA Receive filter comprised of an 8-bit down counter which is loaded with the
value programmed in US_IF. When a falling edge is detected on the RXD pin, the Filter Counter starts counting
down at the Master Clock (MCK) speed. If a rising edge is detected on the RXD pin, the counter stops and is
reloaded with US_IF. If no rising edge is detected when the counter reaches 0, the input of the receiver is driven
low during one bit time.
Figure  31-35.
IrDA Demodulator Operations 
As the IrDA mode uses the same logic as the ISO7816, note that the FI_DI_RATIO field in US_FIDI must be set to
a value higher than 0 in order to assure IrDA communications operate correctly.
3 686 400
57 600
4
0.00%
3.26
20 000 000
57 600
22
1.38%
3.26
32 768 000
57 600
36
1.25%
3.26
40 000 000
57 600
43
0.93%
3.26
3 686 400
38 400
6
0.00%
4.88
20 000 000
38 400
33
1.38%
4.88
32 768 000
38 400
53
0.63%
4.88
40 000 000
38 400
65
0.16%
4.88
3 686 400
19 200
12
0.00%
9.77
20 000 000
19 200
65
0.16%
9.77
32 768 000
19 200
107
0.31%
9.77
40 000 000
19 200
130
0.16%
9.77
3 686 400
9 600
24
0.00%
19.53
20 000 000
9 600
130
0.16%
19.53
32 768 000
9 600
213
0.16%
19.53
40 000 000
9 600
260
0.16%
19.53
3 686 400
2 400
96
0.00%
78.13
20 000 000
2 400
521
0.03%
78.13
32 768 000
2 400
853
0.04%
78.13
Table  31-13.
IrDA Baud Rate Error  (Continued)
Peripheral  Clock
Baud  Rate
CD
Baud  Rate  Error
Pulse  Time
MCK
RXD
Receiver
Input
Pulse
Rejected
6
5
4
3
2
6
1
6
5
4
3
2
0
Pulse 
Accepted
Counter
Value