12.6.6.12SDIV and UDIV
Signed Divide and Unsigned Divide.
Syntax
SDIV{cond} {Rd,} RnRm
UDIV{cond} {Rd,} Rn, Rm
where:
cond
Rd
is the destination register. If Rd is omitted, the destination register is Rn.
Rn
is the register holding the value to be divided.
Rm
is a register holding the divisor.
Operation
SDIV performs a signed integer division of the value in Rn by the value in Rm.
UDIV performs an unsigned integer division of the value in Rn by the value in Rm.
For both instructions, if the value in Rn is not divisible by the value in Rm, the result is rounded towards zero.
Restrictions
Do not use SP and do not use PC
.
Condition Flags
These instructions do not change the flags.
Examples
    SDIV  R0, R2, R4  ; Signed divide, R0 = R2/R4