Atmel SAM4S-XPLD Atmel ATSAM4S-XPLD ATSAM4S-XPLD Hoja De Datos

Los códigos de productos
ATSAM4S-XPLD
Descargar
Página de 1125
 211
SAM4S [DATASHEET]
11100E–ATARM–24-Jul-13
12.10.1.2SysTick Reload Value Registers
Name:
SYST_RVR
Access: Read-write
Reset: 0x000000000 
The SYST_RVR register specifies the start value to load into the SYST_CVR register.
• RELOAD
Value to load into the SYST_CVR register when the counter is enabled and when it reaches 0.
The RELOAD value can be any value in the range 0x00000001-0x00FFFFFF. A start value of 0 is possible, but has no effect 
because the SysTick exception request and COUNTFLAG are activated when counting from 1 to 0.
The RELOAD value is calculated according to its use: For example, to generate a multi-shot timer with a period of N processor 
clock cycles, use a RELOAD value of N-1. If the SysTick interrupt is required every 100 clock pulses, set RELOAD to 99.
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
RELOAD
15
14
13
12
11
10
9
8
RELOAD
7
6
5
4
3
2
1
0
RELOAD