16.6.6 RTC Calendar Alarm Register
Name: RTC_CALALR
Address:
0x400E1474
Access: Read-write
Note:
To change one of the DATE, MONTH fields, it is recommended to disable the field before changing the value and 
then re-enable it after the change has been made. This requires up to 3 accesses to the RTC_CALALR register. The 
first access clears the enable corresponding to the field to change (DATEEN,MTHEN). If the field is already cleared, 
this access is not required. The second access performs the change of the value (DATE,MONTH). The third access is 
required to re-enable the field by writing 1 in DATEEN, MTHEN fields.
• MONTH: Month Alarm
This field is the alarm field corresponding to the BCD-coded month counter.
• MTHEN: Month Alarm Enable
0 = The month-matching alarm is disabled.
1 = The month-matching alarm is enabled.
• DATE: Date Alarm
This field is the alarm field corresponding to the BCD-coded date counter.
• DATEEN: Date Alarm Enable
0 = The date-matching alarm is disabled.
1 = The date-matching alarm is enabled.
31
30
29
28
27
26
25
24
DATEEN
DATE
23
22
21
20
19
18
17
16
MTHEN
MONTH
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0