23.7.9 CRCCU Control Register
Name:   CRCCU_CR
Address:0x40044034
Access: Write-only
Reset:    0x00000000
• RESET: CRC Computation Reset
When set to one, this bit resets the CRCCU_SR register to 0xFFFF FFFF.
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
RESET