Atmel SAM4S-XPLD Atmel ATSAM4S-XPLD ATSAM4S-XPLD Hoja De Datos

Los códigos de productos
ATSAM4S-XPLD
Descargar
Página de 1125
 833
SAM4S [DATASHEET]
11100E–ATARM–24-Jul-13
37.14.6 HSMCI Command Register
Name: HSMCI_CMDR
Address:
0x40000014
Access: Write-only 
 
This register is write-protected while CMDRDY is 0 in HSMCI_SR. If an Interrupt command is sent, this register is only writable by 
an interrupt response (field SPCMD). This means that the current command execution cannot be interrupted or modified.
• CMDNB: Command Number
This is the command index.
• RSPTYP: Response Type
• SPCMD: Special Command
31
30
29
28
27
26
25
24
BOOT_ACK
ATACS
IOSPCMD
23
22
21
20
19
18
17
16
TRTYP
TRDIR
TRCMD
15
14
13
12
11
10
9
8
MAXLAT
OPDCMD
SPCMD
7
6
5
4
3
2
1
0
RSPTYP
CMDNB
Value
Name
Description
0
NORESP
No response.
1
48_BIT
48-bit response.
2
136_BIT
136-bit response.
3
R1B
R1b response type
Value
Name
Description
0
STD
Not a special CMD.
1
INIT
Initialization CMD:
74 clock cycles for initialization sequence.
2
SYNC
Synchronized CMD:
Wait for the end of the current data block transfer before sending the pending command.
3
CE_ATA
CE-ATA Completion Signal disable Command.
The host cancels the ability for the device to return a command completion signal on the 
command line.
4
IT_CMD
Interrupt command:
Corresponds to the Interrupt Mode (CMD40).
5
IT_RESP
Interrupt response:
Corresponds to the Interrupt Mode (CMD40).
6
BOR
Boot Operation Request.
Start a boot operation mode, the host processor can read boot data from the MMC device directly.
7
EBO
End Boot Operation.
This command allows the host processor to terminate the boot operation mode.