Troubleshooting Guide
Table 7-1.  Troubleshooting Guide
Problem
Reason
Solution
The red power LED is not on.
The DC power cable is not 
connected.
Connect the DC power cable 
to the DC jack (page 2-3).
Wrong power supply is used.
Check that the power supply 
is of DC type 10 - 15V, min. 
500 mA (page 2-3).
The power switch is off.
Turn on the power switch.
The preprogrammed 
example code does not 
toggle the LEDs.
There is no AVR device in the 
socket.
Plug the AVR device into the 
right socket (page 2-3).
The LEDs are not connected 
to the I/O ports.
Connect the LEDS header to 
the PORTD header, and the 
SWITCHES header to the 
PORTB header (page 3-3).
The Flash memory is erased.
Connect STK500 to a PC 
and reprogram the AVR 
device (page 2-3).
The AVR device cannot be 
programmed.
The PC serial cable is not 
connected.
Connect the serial cable to 
the PC COM port and the 
RS232 PROG port.
The AVR device is inserted in 
wrong socket.
Check that the correct socket 
is used (page 3-10).
The AVR device is inserted 
with wrong orientation.
Check that the notch on the 
AVR socket matches the 
notch on the AVR device.
The target ISP header is not 
connected.
Connect the 6-pin flexible 
cable from ISP6PIN header 
to the correct SPROG target 
ISP header (page 3-10).
The jumpers settings are 
wrong.
Set jumper to default setup 
(page 3-15).
The memory lock bits are 
programmed.
Erase the memory before 
programming.