Testing the board
AN4260
12/29
DocID024275 Rev 2
The power consumption of the presented board is about six times lower than the limit fixed 
by version 4 of the Code of Conduct. Even though the performance seems to be 
disproportionally better than requirements, it is worth noting that often AC-DC adapter or 
battery charger manufacturers have very strict requirements about no load consumption 
and if the converter is used as an auxiliary power supply, the line filter is often the main line 
filter of the entire power supply that increases greatly the standby consumption.
Even though version 4 of the Code of Conduct does not have other requirements regarding 
light load performance, in order to give a more complete overview, the consumption of the 
demonstration board in two other light load cases (P
OUT
 = 25 mW and P
OUT
 = 50 mW) has 
also been measured. The results versus line voltage are plotted in 
, together with 
the no load measurements reported in 
Figure 16. P
IN
 vs. V
IN
 @ no load and light load
Several criteria can be adopted to measure the performance of a converter. One criterion is 
to measure the output power (or the efficiency) when the input power is equal to 1 Watt. This 
measurement is shown in 
 for different input voltage values.
Table 4. Energy consumption criteria for no load
Nameplate output power (P
no
)
Maximum power in no load for AC-DC EPS
0 to 
  50 W 
< 0.3 W
> 50 W < 250 W
< 0.5 W
0
50
100
150
200
80
105
130
155
180
205
230
255
P
IN
[m
W
]
V
IN
[V
AC
]
0
25mW
50mW
AM16643v1