German RepRap 100258 Hoja De Datos

Descargar
Página de 10
 
 
Product name:
Ingeo
™ biopolymer
___________________________________________________________ 
5.   FIRE FIGHTING MEASURES
Flammability: 
 Autoignition 
temperature: 
388C
 
Flammability Limits in Air: 
 
Flammable limits in air - lower (%): 
Not applicable
 
Flammable limits in air - upper (%): 
Not applicable
 
Suitable extinguishing media: 
Foam. Water. Carbon dioxide (CO2). Dry chemical. Alcohol 
resistant foams are preferred if available. General-purpose synthetic foams (including 
AFFF) or protein foams may function, but much less effectively. 
 
Extinguishing media which must not be used for safety reasons: 
No information available
 
Hazardous decomposition products: 
Burning produces obnoxious and toxic fumes Aldehydes 
Carbon monoxide (CO) carbon dioxide (CO2)
 
Special protective equipment for firefighters: 
As in any fire, wear self-contained 
breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full 
protective gear.
 
Under fire conditions: 
Cool containers / tanks with spray water. Water mist may be used to 
cool closed containers.
 
Other information: 
Fine dust dispersed in air may ignite. Risks of ignition followed by 
flame propagation or secondary explosions shall be prevented by avoiding accumulation of 
dust, e.g. on floors and ledges.
 
6. ACCIDENTAL RELEASE MEASURES
 
Personal precautions: 
Use personal protective equipment. See Section 8. Remove all sources 
of ignition. Avoid dust formation. Avoid contact with skin and eyes. Sweep up to prevent 
slipping hazard.
 
Environmental precautions: 
Do not flush into surface water or sanitary sewer system. Do 
not allow material to contaminate ground water system.
___________________________________________________________ 
The Information Herein Is Given In Good Faith, But No Warranty, Express Or Implied, Is Made.  
Consult the Company for Further Information. 
Ingeo and the Ingeo logo are trademarks or registered trademarks of NatureWorks in the USA and other 
countries. 
NOTICE REGARDING MEDICAL APPLICATION RESTRICTIONS: The company does not recommend any of its 
products, including samples, for use: (A) in any application which is intended for any internal 
contact with human body fluids or body tissues (B) as a critical component in any medical device 
that supports or sustains human life; and (C) specifically pregnant women or in any applications 
designed specifically to promote or interfere with human reproduction. 
 
Page  4 of 10 
Revision date:
04/01/2010 
Print date:
09/16/2010 
Product code:
4
Revision Number:  13