7. MICROMASTER 420 SPECIFICATIONS                                                       International English
MICROMASTER 420 Operating Instructions
101
6SE6400-5AA00-0BP0
Table 7-2
MICROMASTER Performance Ratings
Feature
Specification
Mains Operating Voltage
200 to 240 V 
± 10% 1AC
200 to 240 V 
± 10% 3AC
380 to 480 V 
± 10% 3AC
Power Ranges
200 to 240 V 
± 10% 1AC
0.12kW – 3.0 kW
200 to 240 V 
± 10% 3AC
0.12kW – 5.5 kW
380 to 480 V 
± 10% 3AC
0.37kW – 11.0 kW
FSA [W*H*D]
mm (inches)
FSB [W*H*D]
mm (inches)
FSC [W*H*D]
mm (inches)
Dimensions (Without Gland
Plate)
73
(2.87)
173
(6.81)
149
(5.87)
149
(5.87)
202
(7.95)
172
(6.77)
185
(7.28)
245
(9.65)
195
(7.68)
Protection Level
IP20
Temperature Range
-10
°C to +50°C
Storage Temperature
-40
°C to +70°C
Humidity
95% RH – non-condensing
Operational Altitudes
up to 1000m above sea level without derating
Control Method
Linear V/f ; Quadratic V/f; Flux Current Control (FCC)
Overload Capability
1.5 * nominal output current for 60 seconds (every 300 seconds)
Electromagnetic Compatibility
Optional EMC filters to EN55011 Class A or B, also Internal Class A filters
available
Protection features
Undervoltage , Overvoltage, Ground Faults, Short circuit, Stall Prevention,
Locked Rotor, Motor Overtemperature, Inverter Overtemperature
Input frequency
47 to 63 Hz
Setpoint resolution
0.01Hz Digital, 0.01 Hz Serial, 10 bit Analogue
Switching frequency
2kHz to 16kHz (2kHz steps)
Digital Inputs
3 programmable isolated) inputs, switchable active high / active low
(PNP/NPN)
Fixed frequencies
7 programmable
Skip Frequencies
4 programmable
Relay Outputs
1 programmable 30V DC / 5A (resistive), 250V AC 2A (resistive)
Analogue Input
1 (0/2 to 10V) used for setpoint or PI feedback signal
Analogue Output
1 (0/4 to 20mA) programmable
Serial Interface
RS-232 and RS-485
Design/Manufacture
In accordance with ISO 9001
Standards
UL, cUL, CE, C-tick
CE Marked
Conformity with EC Low Voltage Directive 73/23/EEC
and Electromagnetic Compatibility Directive 89/336/EEC
Power factor
≥0.7
Inverter efficiency
96 to 97 %
Inrush current
Less than nominal input current
Braking
DC braking, compound braking