Siemens MICROMASTER 420 0.25 kW 1-phase frequency inverter, 230 Vac to , 6SE6420-2AB12-5AA1 6SE6420-2AB12-5AA1 Hoja De Datos

Los códigos de productos
6SE6420-2AB12-5AA1
Descargar
Página de 130
5. SYSTEM PARAMETERS                                                                                International English
MICROMASTER 420 Operating Instructions
45
6SE6400-5AA00-0BP0
5.2.4 
Parameter Overview Levels 1 and 2
The following is an overview of Level 1 and 2 parameters. For a complete description of
all Level 1 and 2 parameters, see Section 5.3.
Quick Commissioning P0010=1
Inverter Unit P0004=2
P 0100
Europe / North America 

P
0003
BOP/AOP read access level
P 0300
Select motor type 

P
0010
Drive commissioning
P 0304
Rated motor voltage 

r
0018
Firmware version
P 0305
Rated motor current 

r
0026
Act. DC-link voltage
P 0307
Rated motor power 

r
0039
Power consumption [kWh]
P 0308
Rated motor cosPhi 

P
0040
Reset power consumption
P 0309
Rated motor efficiency 

r
0206
Rated drive power
P 0310
Rated motor frequency 

r
0207
Rated drive current
P 0311
Rated motor speed 

r
0208
Rated drive voltage
P 0335
Motor cooling 

P
1800
Switching frequency
P 0640
Max. output current
P
1820
Reverse output phase sequence
P 0700
Command of PZD via
P 1000
Selection of frequency setpoint
P 1080
Min. frequency
P 1082
Max. frequency
P 1120
Ramp-up time
P 1121
Ramp-down time
P 1135
OFF3 Ramp-down time
P 1300
Control mode
P 3900
Quick parameterization 

Motor Data P0004=3
Commands and Digital I/O P0004=7
P
0003 BOP/AOP read access level
r
0002
Drive state
P
0010 Drive commissioning
P
0003
BOP/AOP read access level
r
0034 Motor utilization
P
0010
Drive commissioning
P
0300 Select motor type 

r
0052
Statusword 1
P
0304 Rated motor voltage 

r
0053
Statusword 2
P
0305 Rated motor current 

P
0700
Command of PZD via
P
0307 Rated motor power (kW or hp) 
 P
0701
Selection digital input1
P
0308 Rated motor cosPhi 

P
0702
Selection digital input2
P
0309 Rated motor efficiency 

P
0703
Selection digital input3
P
0310 Rated motor frequency 

P
0704
Selection digital input4
P
0311 Rated motor speed 

r
0722
Binary input values
P
0335 Motor cooling 

P
0731
Binary output
P
0340 Calc motor model and control
P
0350 Stator resistance phase-to-phase
P
0611 Motor I
2
t time constant
P
0614 Motor I
2
t overload warning level
P
0640 Max. output current
P
1910 Select motor data identification
r
1912 Identified stator resistance