Phoenix Contact 2814715 MCR-S-1/5-UI-DCI-NC Active Current Measuring Transducer Upto 11 A 2814715 Hoja De Datos

Los códigos de productos
2814715
Descargar
Página de 68
27
Reliable isolation 
• I/O (Analog), I/O (Relay) 
2)
,I/O (Transistor), I/S
acc. to EN 50178, EN 61010:
 
300 V AC to earth 
3)
Test voltage:
• I/O (Analog), I/O (Relay), I/O (Transistor), I/S
• O (Analog)/O (Relay), O (Relay)/O (Transistor)
• O(Analog)/O(Transistor), O (Analog)/S
4 kV, 50 Hz, 1 min.
4 kV, 50 Hz, 1 min.
500 V, 50 Hz, 1 min.
Surge voltage category
III
Contamination class
2
Ambient temperature range
operation
storage
-20 °C to +60 °C
-40 °C to +85 °C
Module warm-up time
> 2 min.
Function standby signal
green LED
Protection type
IP 20
Installation position/mounting
any
Dimensions (W / H / D) in mm
22.5 x 99 x 114.5
Conductor cross section
0.2 – 2.5 mm
2
 (AWG 24-14)
Type of housing
polyamide PA non-reinforced
1)
If the maximum values indicated are exceeded, the gold layer is destroyed! The following max.
 
switching voltages and currents are then valid for further operation: 250 V AC/DC; 2A.
2)
 I 
=
 Input / O 
=
 Output / S 
=
 Supply
3)
 Suitable for measuring in 400 V AC three-phase system.
Conformity / approvals
c
Conformance with 
low voltage directive
2006/95/EC
Conformance with 
EMC 
directive
2004/108/EC
Immunity to interference
according to
EN 61000-6-2
Noise emission
according to
EN 61000-6-4
UL approval
 
U
 
 LISTED
PROCESS CONTROL EQUIPMENT
FOR HAZARDOUS LOCATIONS
31ZN
Cl. I, Zn. 2, AEx nC IIC T6 / Ex nC IIC T6
Cl. I Div. 2, Groups A, B, C and D or Non-Hazardous Locations Only
A) This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or 
 
non-hazardous locations only.
B) Warning - explosion hazard - substitution of components may impair suitability 
for Class 1, Division 2,/Zone 2.
C) Warning - explosion hazard - do not disconnect equipment unless power has 
been switched off or the area is known to be non-hazardous.
6. Technical data