Bourns Multifuse cutoffs 32 V (L x W x H) 1.6 x 0.8 x 0.45 mm SF-0603F200-2 1 pc(s) SF-0603F200-2 Hoja De Datos
Los códigos de productos
SF-0603F200-2
■
Single blow fuse for overcurrent
protection
■
1608 (EIA 0603) miniature footprint
■
Fast-acting fuse
■
UL listed
■
RoHS compliant* and halogen free**
■
Thin fi lm chip fuse
■
Surface mount packaging for automated
assembly
Electrical Characteristics
SF-0603F Series - Fast Acting Surface Mount Fuses
* RoHS Directive 2002/95/EC Jan 27 2003 including Annex.
** Bourns is using the defi nition that appears to be the prevalent defi nition used as the industry standard at this time. The Bourns defi nition of “halogen-free” is:
** Bourns is using the defi nition that appears to be the prevalent defi nition used as the industry standard at this time. The Bourns defi nition of “halogen-free” is:
Bromine (Br) content:
≤ 900 ppm; Chlorine (Cl) content: ≤ 900 ppm; Total Br + Cl content: ≤1500 ppm.
“SinglFuse” is a trademark of Bourns, Inc.
Specifi cations are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specifi c applications.
Specifi cations are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specifi c applications.
***Resistance value was measured with less than 10 % of rated current.
Reliability Testing
Parameter Requirement
Test
Method
Carrying Capacity ..................................... No fusing ....................................................Rated current, 4 hours
Fusing Time .............................................. Within 1 minute ..........................................200 % of its rated current
Interrupting Ability ..................................... No mechanical damages ...........................After the fuse is interrupted, rated voltage applied for
Fusing Time .............................................. Within 1 minute ..........................................200 % of its rated current
Interrupting Ability ..................................... No mechanical damages ...........................After the fuse is interrupted, rated voltage applied for
30 seconds again
Bending Test ............................................. No mechanical damages ...........................Distance between holding points: 90 mm,
Bending: 3 mm,1time, 30 seconds
Resistance to Solder Heat ........................ ±20 % .........................................................260 °C ±5 °C,10 seconds ±1 second
Solderability .............................................. 95 % coverage minimum ...........................235 °C ±5 °C, 2 ±0.5 second
Solderability .............................................. 95 % coverage minimum ...........................235 °C ±5 °C, 2 ±0.5 second
245 °C ±5 °C, 2 ±0.5 second (lead free)
Temperature Rise ..................................... <75 ° ..........................................................100 % of its rated current, measure of surface
temperature
Resistance to Dry Heat............................. ±20 % .........................................................105 °C ±5 °C,1000 hours
Resistance to Solvent ............................... No evident damage on protective ..............23 °C ±5 °C of isopropyl alcohol, 90 seconds coating
and
temperature
Resistance to Dry Heat............................. ±20 % .........................................................105 °C ±5 °C,1000 hours
Resistance to Solvent ............................... No evident damage on protective ..............23 °C ±5 °C of isopropyl alcohol, 90 seconds coating
and
marking
Residual Resistance ................................. 10k W or more ...........................................Measure DC resistance after fusing
Thermal Shock ......................................... DR < 10 % .................................................-20 °C / +25 °C /+125 °C /+25 °C, 10 cycles
Thermal Shock ......................................... DR < 10 % .................................................-20 °C / +25 °C /+125 °C /+25 °C, 10 cycles
Typical Part Marking
Represents total content. Layout may
vary.
vary.
How to Order
SF - 0603 F 050 - 2
SinglFuse™
Product Designator
Product Designator
SMD Footprint
1608 (EIA 0603) size
1608 (EIA 0603) size
Fuse Blow Type
F = Fast acting
S = Slow blow
Rated Current
050-500 (500 mA - 5.00 A)
Packaging Type
- 2 = Tape & Reel (5,000 pcs./reel)
Model
Rated Current
(Amps)
Fusing Time
Resistance
(m
Ω) Typ.***
Rated Voltage Breaking Capacity
Typical
I
2
t (A
2
s)
SF-0603F050
0.50
Open within 1 min.
at 200 % rated
current
250
DC 50 V
DC 50 V
50 A
0.005
SF-0603F063
0.63
173
DC 32 V
DC 32 V
50 A
0.007
SF-0603F080
0.80
115
0.014
SF-0603F100
1.00
88
0.016
SF-0603F125
1.25
63
0.027
SF-0603F150
1.50
45
0.037
SF-0603F160
1.60
42
0.041
SF-0603F200
2.00
33
0.044
SF-0603F250
2.50
24
DC 24 V
DC 24 V
50 A
0.055
SF-0603F300
3.00
21
0.082
SF-0603F315
3.15
19
0.089
SF-0603F400
4.00
15
DC 32 V
DC 32 V
50 A
0.239
SF-0603F500
5.00
12
0.433
RATING CURRENT (A)
F = 0.50
I = 0.63
K = 0.80
L = 1.00
M = 1.25
P = 1.50
N = 1.60
F = 0.50
I = 0.63
K = 0.80
L = 1.00
M = 1.25
P = 1.50
N = 1.60
S = 2.00
T = 2.50
3 = 3.00
U = 3.15
W = 4.00
Y = 5.00
T = 2.50
3 = 3.00
U = 3.15
W = 4.00
Y = 5.00
SinglFuse
™
SF-0603F Series Features
*RoHS COMPLIANT
Asia-Pacifi c:
Tel: +886-2 2562-4117
Fax: +886-2 2562-4116
Tel: +886-2 2562-4117
Fax: +886-2 2562-4116
Europe:
Tel: +41-41 768 5555
Fax: +41-41 768 5510
Tel: +41-41 768 5555
Fax: +41-41 768 5510
The Americas:
Tel: +1-951 781-5500
Fax: +1-951 781-5700
Tel: +1-951 781-5500
Fax: +1-951 781-5700