Hamlin DRR-129 Standard-Reed-Switch 1 closure 3 A 400 Vdc 100 W DRR-129 Hoja De Datos
Los códigos de productos
DRR-129
DRR-129 Features and Benefits
DIMENSIONS (in) mm
Notes
1) For details on electrical specifications, contact Hamlin.
2) Contact rating-Product of the switching voltage and current should never exceed the
wattage rating.
Contact Hamlin for additional load/life information.
Contact Hamlin for additional load/life information.
3) Operate/Release Time-per EIA/NARM RS421A, diode suppressed coil.
4) Pull in Range-Contact Hamlin for tolerances available within this range.
5) Rating Sensitivity-The value at which contact ratings and operating characteristics are
determined. Derating may be required below this value.
6) Storage Temperature-Long time exposure at elevated temperature may degrade
solderability of the leads.
Switch Type
DRR-129
Contact Form
A
Underwriters Laboratories Recognised, File E47258 (see note 1)
ELECTRICAL RATINGS
Contact Rating (2)
Watt - max.
100
Voltage
Switching
Vdc - max.
400
Breakdown
Vdc - min.
600
Current
Switching
A - max.
3.0
Carry
A - max.
6.0
Resistance
Contact, Initial
Ω
- max.
0.100
Insulation
Ω
- min.
10
10
Capacitance
Contact
pF - typ.
0.6
Temperature
Operating
°C
-40 to +125
Storage (6)
°C
-65 to +125
OPERATING CHARACTERISTICS
Operate Time (3)
ms - max.
4.5
Release Time (3)
ms - max.
2.5
Shock
11ms
1
⁄
2
sine wave
G - max.
100
Vibration
50-2000 Hertz
G - max.
30
Resonant Frequency
Hz - typ.
850
MAGNETIC CHARACTERISTICS
Pull-In Range (4)
Ampere Turns
42-83
Rating Sensitivity (5)
Ampere Turns
60
Test Coil
L4988
Features
•
Normally open switch size with
50.80mm x 5.25mm (2.0” x
0.207”) glass envelope
50.80mm x 5.25mm (2.0” x
0.207”) glass envelope
•
Capable of switching up to
400Vdc
400Vdc
•
Maximum switched current 3
Amps, will carry up to 6 Amps
Amps, will carry up to 6 Amps
•
Maximum contact rating 100 Watts
•
Minimum voltage breakdown 600Vdc
•
10
10
Ohms insulation resistance
•
Available sensitivity range 42-83 AT
Benefits
•
Hermetically sealed switch
contacts are not effected by and
have no effect on their external
environment
contacts are not effected by and
have no effect on their external
environment
•
Capable of switching European
mains voltage
mains voltage
•
Low, stable contact resistance
•
Low space requirement
•
Zero operating power required
for contact closure
for contact closure
•
Fit and forget durability
Applications
•
Security
•
Limit switching
•
Automotive applications
•
Industrial safety applications
INFORMATION PROVIDED ON THIS DATA SHEET IS PROVIDED FOR INFORMATION PURPOSES ONLY AND SHOULD NOT BE RELIED UPON AS BEING ACCURATE FOR ANY
PARTICULAR PURPOSE. Product performance may be affected by the application to which the product is
PARTICULAR PURPOSE. Product performance may be affected by the application to which the product is
applied. Upon request, HAMLIN will assist purchasers by providing information
specific to any particular application. HAMLIN disclaims any and all liability whatsoever for any purchaser’s reliance upon the information contained on this data sheet without further
consultation with authorised representatives of HAMLIN.
consultation with authorised representatives of HAMLIN.
USA Tel: +1 920 648 3000
•
Fax: +1 920 648 3001
•
Email: sales
.us@hamlin.com
UK Tel: +44 (0)1379 649700
•
Fax: +44 (0)1379 649702
•
Email: sales
.uk@hamlin.com
Germany Tel: +49 (0) 6
142 923920
•
Fax: +49 (0) 61
42 923921
•
Email:
sales.de@hamlin.com
France Tel: +33
(0) 1 6047 3000
•
Fax: +33
(0) 1 6015 9136
•
Email:
sales.fr@hamlin.com
ISSUE No: 3 DATE: 28/09/0