Finder 80.91.0.240.0000 - 16A Monofunction Modular Timer SPDT-CO 400Vac IP20 80.91.0.240.0000 Hoja De Datos

Los códigos de productos
80.91.0.240.0000
Descargar
Página de 8
80.21
80.41
80.91
Multi-voltage
Mono-function
LI: Asymmetrical flasher 
(starting pulse on)
LE: Asymmetrical flasher (starting 
pulse on) with control signal
Wiring diagram
(without control
signal)
Wiring diagram
(with control 
signal)
1 CO (SPDT)
1 CO (SPDT)
1 CO (SPDT)
16/30
16/30
16/30
250/400
250/400
250/400
4,000
4,000
4,000
750
750
750
0.55
0.55
0.55
16/0.3/0.12
16/0.3/0.12
16/0.3/0.12
500 (10/5)
500 (10/5)
500 (10/5)
AgCdO
AgCdO
AgCdO
24...240
24...240
12...240
24...240
24...240
12...240
< 1.8 / < 1
< 1.8 / < 1
< 1.8 / < 1
16.8...265
16.8...265
10.8...265
16.8...265
16.8...265
10.8...265
(0.1…2)s, (1…20)s, (0.1…2)min, (1…20)min, (0.1…2)h, (1…24)h
± 1
± 1
± 1
100
100
100
50
50
± 5
± 5
± 5
100·10
3
100·10
3
100·10
3
–10…+50
–10…+50
–10…+50
IP 20
IP 20
IP 20
Multi-voltage
Mono-function
DI: Interval
Wiring diagram
(without control signal)
Contact specification
Contact configuration
Rated current/Maximum peak current
A
Rated voltage/Maximum switching voltage V AC
Rated load AC1  
VA
Rated load AC15 (230 V AC)
VA
Single phase motor rating (230 V AC) 
kW
Breaking capacity DC1: 30/110/220 V
A
Minimum switching load
mW (V/mA)
Standard contact material
Supply specification
Nominal voltage (U
N
)
V AC (50/60 Hz)
V DC
Rated power AC/DC
VA (50 Hz)/W
Operating range
V AC
V DC
Technical data
Specified time range
Repeatability
%
Recovery time
ms
Minimum control impulse
ms
Setting accuracy-full range
%
Electrical life at rated load in AC1
cycles
Ambient temperature range
°C
Protection category
Approvals (according to type)
Features
Mono-function timer range
80.21 - Interval, multi-voltage
80.41 - Off-delay with control signal, multi-voltage
80.91 - Asymmetrical flasher, multi-voltage
17.5 mm wide
Six time scales from 0.1s to 24h
High input/output isolation
35 mm rail (EN 60715) mount
“Blade + cross” - both flat blade and cross head 
screw drivers can be used to adjust the range 
and function selectors, the timing trimmer, and 
to disengage the rail mounting clip 
New multi-voltage versions with “PWM clever”
technology 
80.21 / 80.41 / 80.91
Screw terminal
F
OR
UL 
RATINGS SEE
“General technical information” page V
For outline drawing see page 6
Wiring diagram
(with control signal)
Multi-voltage
Mono-function
BE: Off-delay with control signal
2
80 Series - Modular timers 16 A
VII-2012, www
.finder
net.com