Finder 80.91.0.240.0000 - 16A Monofunction Modular Timer SPDT-CO 400Vac IP20 80.91.0.240.0000 Hoja De Datos
Los códigos de productos
80.91.0.240.0000
80.21
80.41
80.91
•
Multi-voltage
•
Mono-function
LI: Asymmetrical flasher
(starting pulse on)
LE: Asymmetrical flasher (starting
pulse on) with control signal
Wiring diagram
(without control
signal)
Wiring diagram
(with control
signal)
1 CO (SPDT)
1 CO (SPDT)
1 CO (SPDT)
16/30
16/30
16/30
250/400
250/400
250/400
4,000
4,000
4,000
750
750
750
0.55
0.55
0.55
16/0.3/0.12
16/0.3/0.12
16/0.3/0.12
500 (10/5)
500 (10/5)
500 (10/5)
AgCdO
AgCdO
AgCdO
24...240
24...240
12...240
24...240
24...240
12...240
< 1.8 / < 1
< 1.8 / < 1
< 1.8 / < 1
16.8...265
16.8...265
10.8...265
16.8...265
16.8...265
10.8...265
(0.1…2)s, (1…20)s, (0.1…2)min, (1…20)min, (0.1…2)h, (1…24)h
± 1
± 1
± 1
100
100
100
—
50
50
± 5
± 5
± 5
100·10
3
100·10
3
100·10
3
–10…+50
–10…+50
–10…+50
IP 20
IP 20
IP 20
•
Multi-voltage
•
Mono-function
DI: Interval
Wiring diagram
(without control signal)
Contact specification
Contact configuration
Rated current/Maximum peak current
A
Rated voltage/Maximum switching voltage V AC
Rated load AC1
VA
Rated load AC15 (230 V AC)
VA
Single phase motor rating (230 V AC)
kW
Breaking capacity DC1: 30/110/220 V
A
Minimum switching load
mW (V/mA)
Standard contact material
Supply specification
Nominal voltage (U
N
)
V AC (50/60 Hz)
V DC
Rated power AC/DC
VA (50 Hz)/W
Operating range
V AC
V DC
Technical data
Specified time range
Repeatability
%
Recovery time
ms
Minimum control impulse
ms
Setting accuracy-full range
%
Electrical life at rated load in AC1
cycles
Ambient temperature range
°C
Protection category
Approvals (according to type)
Features
Mono-function timer range
80.21 - Interval, multi-voltage
80.41 - Off-delay with control signal, multi-voltage
80.91 - Asymmetrical flasher, multi-voltage
80.41 - Off-delay with control signal, multi-voltage
80.91 - Asymmetrical flasher, multi-voltage
•
17.5 mm wide
•
Six time scales from 0.1s to 24h
•
High input/output isolation
•
35 mm rail (EN 60715) mount
•
“Blade + cross” - both flat blade and cross head
screw drivers can be used to adjust the range
and function selectors, the timing trimmer, and
to disengage the rail mounting clip
screw drivers can be used to adjust the range
and function selectors, the timing trimmer, and
to disengage the rail mounting clip
•
New multi-voltage versions with “PWM clever”
technology
technology
80.21 / 80.41 / 80.91
Screw terminal
Screw terminal
F
OR
UL
RATINGS SEE
:
“General technical information” page V
For outline drawing see page 6
Wiring diagram
(with control signal)
•
Multi-voltage
•
Mono-function
BE: Off-delay with control signal
2
80 Series - Modular timers 16 A
VII-2012, www
.finder
net.com