Description and Mounting Instructions
LED Driver with constant output current for the operation of LED
(Electronic power supply unit)
MODEL: 464210
Protection class 2
CE
1. Technical Data:
464210
(LLVC15BDE UNI)
Rated voltage
100-240V 50-60Hz
Share load operation
5-15W
Constant output current
0.7 - 1.0 - 1.2 A
Secondary voltage
3-12VDC SELV equivalent
Open-circuit safety
Guaranteed
Ambient temperature ta
-20° C - +50°C
Casing temperature tc-point
75°C
Standards
EN 61347, EN 62384
EMV conformity
EN 61547, EN 55015, EN 61000-3-2, EN 61000-3-3
Primary main
Min. H03VV-F 2x0,75 mm², for pull relief
Secondary main
Min. H03VV-F 2x0,75 mm², for pull relief
PRI
0,5 – 1,5mm²
AWG 20-16
Diameter of wires
SEC
0,75 – 1,5mm²
AWG 22-14
PRI 9mm
Cable (Terminals)
Bared wire end
SEC 6mm
2. Installation Instructions
The installation may only be carried out by an electrical specialist in accordance with international and
national standards.
When working on electrical systems, protection against electric shock is to be ensured by disconnecting the
system. Install primary and secondary mains intersection-free (RFI protection).
!Before switching on the supply voltage all LED must be completely wired and connected!
!Before switching on the supply voltage all LED must be completely wired and connected!
The LED Driver is strictly suited for the use with LED that require a constant current.
When connecting the LED, careful attention should be paid to connecting + and - to the right terminals on the LED
Driver.
LED Drivers mounted outside of luminaries are to be screwed tightly to the respective surface by their screw holes and
careful attention is to be paid to the connecting cables and the lamp cables being fastened securely in the strain relief.
LED Drivers mounted outside of luminaries are to be screwed tightly to the respective surface by their screw holes and
careful attention is to be paid to the connecting cables and the lamp cables being fastened securely in the strain relief.
The tc temperature may not be exceeded for any kind of mounting. The devices do not contain any serviceable
components and may not be opened.
3. Important Information
Our LED Drivers are surge-voltage-stable with values above those prescribed by the respective standards. As a
protection against high voltage surges, as they occur e.g. when switching fluorescent lamps and discharge lamps with
an inductive ballast, motors (fans, etc.) and other inductive charges, the load circuits for devices of this kind are to be
clearly separated from each other.
!The LED Driver cannot be regulated via a phase cut-on or cut-off dimmer!
4. Safety Functions
In case of a short circuit or overload the LED Driver will automatically cut off. It does not have a fuse of the conventional
In case of a short circuit or overload the LED Driver will automatically cut off. It does not have a fuse of the conventional
kind. Thus the load circuit is not separated!
As soon as the defect has been repaired, the LED Driver will automatically cut back in.
5. Excess Temperature
In case of excess temperature through external heat sources or impermissible covers the build-in over temperature
control will reduce power. As soon as the LED Driver has cooled off, it will automatically cut back in.
6. Heat Dissipation and Heat Transfer
Operation in excess ambient temperature or through external heating will reduce the service life. During the installation
process (particularly into luminaries), heat dissipation (heat transfer) is to be provided through suitable measures. The
ambient temperature and/or tc temperature may not be exceeded at any time. We are not liable for damage resulting
from improper use.
Art.-No. 464210
03/2010
© SLV Elektronik GmbH, Daimlerstr. 21-23, 52531 Übach-Palenberg,
Germany, Tel. +49 (0)2451 4833-0
Technical properties subject to modification
Germany, Tel. +49 (0)2451 4833-0
Technical properties subject to modification