Application Specification                   114-106078 
Jul 11
th
, 2013   Rev. C1 
This specification is a controlled document.                                      Page 7 of 12 
 
© Copyright 2012 by TE Connectivity Corporation 
All rights reserved 
3.3  Assembly of Connectors 
3.3.1  Selection of Sealing & Pinch Ring for Connectors 
The connector should select a suitable sealing & pinch ring for assembly according to the outside 
diameter of the cable. 
Pinch Ring selection criterion: Suppose the general tolerance is ±0.2mm max. of 
cable Outside Diameter (OD), if norminal OD of cable is less than or equal 6.0mm, 
1740379-2 is preferred, if norminal OD of cable is bigger than 6.0mm, 1987981-2 
is preferred. 
 
Cable Outside Diameter 
Pinch Ring Type 
Picture 
From 5.8 up to 8.0mm 
1987981-2 
 
From 5.1 up to 6.2mm 
1740379-2 
 
Table 4 
Use only PV1-F wire  according to PfG 2 1169 / 08.07  or 2 PfG 
1990 / 5.12  (TUV)  or PV wire type ZKLA according  to UL 4703 or USE-2 cable 
according to UL854. 
The used wire size (mm²/AWG)  and the cable outer diameter must be according 
to the information provided in the Tabel 2 and Table 4.
 
3.3.2  Assembly of the connectors 
The assembly of the connectors must be performed in the following sequence: 
Point 1-2 do not apply for prefabricated connector in this case the contact 
crimped wire lead of cable has to be inserted directly into the correct 
preassembled connector housing 
 
1)  The engagement of the Sealing & Pinch Ring into the connector housing until it stop 
(see Figure 5 and 6)  
 
 
Figure 5  
Connector Housing Components