HS5D Miniature Interlock Switches
6.4 max.
17.4max.
4.2 to 5.8
ø3.2
A
7-31, Nishi-Miyahara 1-Chome, Yodogawa-ku, Osaka 532-8550, Japan
Tel: +81-6-6398-2571, Fax: +81-6-6392-9731
E-mail: marketing@idec.co.jp
Specifications and other descriptions in this catalog are subject to change without notice.
Cat. No. EP1285-1 MARCH 2010 5.4S PRINTED IN JAPAN
IDEC ELECTRONICS LIMITED
Tel: +44-1256-321000, Fax: +44-1256-327755
E-mail: sales@uk.idec.com
IDEC ELEKTROTECHNIK GmbH
Tel: +49-40-25 30 54 - 0, Fax: +49-40-25 30 54 - 24
E-mail: service@idec.de
IDEC (SHANGHAI) CORPORATION
Tel: +86-21-5353-1000, Fax: +86-21-5353-1263
E-mail: idec@cn.idec.com
IDEC (BEIJING) CORPORATION
Tel: +86-10-6581-6131, Fax: +86-10-6581-5119
IDEC (SHENZHEN) CORPORATION
Tel: +86-755-8356-2977, Fax: +86-755-8356-2944
IDEC IZUMI (H.K.) CO., LTD.
Tel: +852-2803-8989, Fax: +852-2565-0171
E-mail: info@hk.idec.com
IDEC TAIWAN CORPORATION
Tel: +886-2-2698-3929, Fax: +886-2-2698-3931
E-mail: service@tw.idec.com
IDEC IZUMI ASIA PTE. LTD.
Tel: +65-6746-1155, Fax: +65-6844-5995
E-mail: info@sg.idec.com
www.idec.com
IDEC CORPORATION (USA)
Tel: +1-408-747-0550 / (800) 262-IDEC (4332) 
Fax: +1-408-744-9055 / (800) 635-6246
E-mail: opencontact@idec.com
IDEC CANADA LIMITED
Tel: +1-905-890-8561, Toll Free: (888) 317-4332 
Fax: +1-905-890-8562
E-mail: sales@ca.idec.com
IDEC AUSTRALIA PTY. LTD.
Tel: +61-3-9763-3244, Toll Free: 1800-68-4332
Fax: +61-3-9763-3255
E-mail: sales@au.idec.com
Instructions
Rotating the Head
The head of the HS5D can be rotated by removing the 
 
four screws from the corners of the HS5D head and rein-
stalling the head in the desired orientation. When reinstall-
ing the head, make sure that no foreign object enters the 
interlock switch. Tighten the screws tightly, because loose 
tightening may cause malfunction.
Recommended screw tightening torque: 0.9 to 1.1 N·m
 
Alternative Head Orientations
Factory Setting
Head Removal Detection Function
Only the NC contact of the main circuit (11-12) turns OFF 
(open) when the head is removed, such as when rotating 
the head. Because NC contacts of other than the main cir-
cuit (11-12) turn ON (closed), be sure to connect the main 
circuit (11-12) to the safety circuit.
Recommended Tightening Torque 
Interlock Switch Mounting Screw: 1.8 ± 2.2 N·m 
 
 
 
 
 
(two M4 screws) 
Housing Lid Screw: 0.2 to 0.4 N·m (M3 screw)
 
Terminal Screw: 
0.6 to 0.8 N·m (M3 screw)
 
Connector: 
2.7 to 3.3 N·m 
 
Actuators 
 
HS9Z-A51: 
 1.8 ± 2.2 N·m (two M4 screws)  
HS9Z-A52: 
 0.8 ± 1.2 N·m (two M4 Phillips screws) 
HS9Z-A51A/A52A:  1.0 to 1.5 N·m (two M4 screws)  
HS9Z-A55: 
 1.0 to 1.5 N·m (two M4 screws)
The above recommended tightening torques of the mount-
 
ing screws are the values confirmed with hex socket head 
bolts. When other screws are used and tightened to a 
smaller torque, make sure that the screws do not come 
loose after mounting.
Mounting bolts must be provided by the user.
 
To avoid unauthorized or unintended removal of the 
 
interlock switch and the actuator, it is recommended that 
the interlock switch and the actuator be installed in an 
unremovable manner, for example using special screws or 
welding the screws.
Applicable Crimping Terminal
When using crimping terminals, be sure to install insulation 
tubes on the crimping terminals to prevent electric shocks.
When using stranded wires, make sure that loose wires do 
not cause short circuit. Also do not solder the terminal to 
prevent loose wires.
Recommended manufacturer: JST
Part No.: N0.5-3
Applicable wire size (with insulation tube): 0.2 to 0.5 mm
2
Note:  Do not remove screw A during wiring. Removing the screw 
may cause malfunction or damage.
Applicable Wire Size
0.5 to 1.5 mm
2
Applicable Cable Glands
Use a cable gland with a degree of protection IP67.
30 max.
9 max.
G1/2, PG13.5, M20
When Using Flexible Conduits (Example)
Flexible conduit example: VF-03 (made by Nihon Flex)
 
Gland Port Size Plastic Cable Gland
Metal Cable Gland
G1/2
RLC-103 (Nihon Flex)
PG13.5
RBC-103PG13.5 (Nihon Flex)
M20
RLC-103EC20 (Nihon Flex)
When Using Multi-core Cables (Example)
Gland Port Size
Plastic Cable Gland
Metal Cable Gland
G1/2
SCS-10* (Seiwa Electric)
ALS-16** (Nihon Flex)
PG13.5
ST13.5 (LAPP)
ABS-**PG13.5 (Nihon Flex)
M20
ST-M20X1.5 (LAPP)
ALS-**EC20 (Nihon Flex)
Different cable glands are used depending on the cable 
 
sheath diameter. When purchasing a cable gland,         
confirm that the cable gland is applicable to the cable 
sheath diameter.
When using a 1/2-14NPT cable gland, use the HS5D 
 
interlock switch with M20 gland port (Type No.: HS5D-
***BM) together with an adaptor (Type No.: MA-M/NPT 
20X1.5 5402-0110, LAPP) and a gasket (Type No.: GP 
M20, LAPP). Install a gasket between the interlock switch 
and the adaptor. Apply sealing tape between the cable 
gland and the adaptor to make sure of IP67 protection for 
the enclosure.
(100405)