3.3.3.2 
Installing the Processor Heatsink(s) 
 
CAUTION: The heatsink has Thermal Interface Material (TIM) located on the bottom of it. Use caution 
when you unpack the heatsink so you do not damage the TIM
 
To install the heatsink, follow these steps:  
1.  Remove the protective film on the TIM if present.  
2.  Orient the heatsink over the processor as shown in Figure 14. The heatsink fins must 
be positioned as shown to provide correct airflow through the system.  
3.  Set the heatsink over the processor, lining up the four captive screws with the four 
posts surrounding the processor.  
4.  Loosely screw in the captive screws on the heatsink corners in a diagonal manner 
according to the numbers shown in as follows:  
a)  Starting with the screw at location 1, engage the screw threads by giving it two 
rotations in the clockwise direction and stop. (IMPORTANT: Do not fully 
tighten.)  
b)  Proceed to the screw at location 2 and engage the screw threads by giving it two 
rotations and stop.  
c)  Engage screws at locations 3 and 4 by giving each screw two rotations and then 
stop.  
d)  Repeat steps 4a through 4c by giving each screw two rotations each time until all 
screws are lightly tightened up to a maximum of 8 inch-lbs torque.