Intel S5500WBR Manual De Usuario

Descargar
Página de 117
Intel® Server Board S5500WB TPS 
Connector/Header Locations and Pin-out 
Revision 1.9 
 
Intel order number E53971-008 
59 
7.3.7 
Chassis ID LED 
The chassis ID LED provides a visual indication of a system being serviced. The state of the 
chassis ID LED is affected by the following: 
  Toggled by the chassis ID button 
  Controlled by the Chassis Identify command (IPMI) 
  Controlled by the Chassis Identify LED command (OEM) 
 
Table 36. Chassis ID LED Indicator States 
State 
LED State 
Identify active via button 
Solid on 
Identify active via command 
~1 Hz blink 
Off 
Off 
 
There is no precedence or lock-out mechanism for the control sources. When a new request 
arrives, all previous requests are terminated. For example, if the chassis ID LED is blinking and 
the chassis ID button is pressed, then the chassis ID LED changes to solid on. If the button is 
pressed again with no intervening commands, the chassis ID LED turns off. 
7.4  I/O Connectors 
7.4.1 
PCI Express* Connectors 
The Intel
®
 Server Board S5500WB has two PCI Express slots. The pin-outs for the slots are 
shown in the following tables. 
Table 37. Slot 6 Riser Connector (J4B1) 
 
Pin 
Side 
PCI Express* Signal 
PCI Express* Signal 
Pin 
Side 
 
Pin 
Side 
PCI Express* Signal 
PCI Express* Signal 
Pin 
Side 
12V 
PRSNT1# 
 
41 
PETxP6 
GND 
41 
12V 
12V 
 
42 
PETxN6 
GND 
42 
RSVD 
12V 
 
43 
GND 
PERxP6 
43 
GND 
GND 
 
44 
GND 
PERxN6 
44 
SMCLK 
JTAG2 
 
45 
PETxP7 
GND 
45 
SMDATA 
JTAG3 
 
46 
PETxN7 
GND 
46 
GND 
JTAG4 
 
47 
GND 
PERxP7 
47 
3.3V 
JTAG5 
 
48 
PRSNT2# 
PERxN7 
48 
JTAG1 
3.3V 
 
49 
GND 
GND 
49 
10 
3.3VAUX 
3.3V 
10 
 
50 
PETxP8 
RSVD 
50 
11 
WAKE# 
PERST# 
11 
 
51 
PETxN8 
GND 
51 
KEY 
KEY 
KEY 
KEY 
 
52 
GND 
PERxP8 
52 
KEY 
KEY 
KEY 
KEY 
 
53 
GND 
PERxN8 
53 
12 
RSVD 
GND 
12 
 
54 
PETxP9 
GND 